Usage recommendation
- Sun protection
- Venetian blind/shutter
Product highlights
Settings not lost even when battery changed
Setting the threshold values possible directly on the device
Integrated transmission pilot lights
Overload detection, e.g. by pool of water
Control button directly on the device
Slim surface-mounted housing
Optimum monitoring of wind movements directly on the front section of the awning
Discrete mounting directly on front section
In plastic housing
General product data
GTIN
4251852908372
Sales unit
pc.
Series
Sensors
RRP (incl. VAT)
196,00 €
Item number
4033 000 210 0
Designation
Centronic SensorControl SC211-II
Technical data
Mains frequency
0 Hz
Battery type
AAA
Can be integrated into the switch frame
no
Colour
White
Length
140 mm
Weight
0.182 kg
Wall bracket included
Dimensions
B x H x T: 23 x 140 x 39 mm
Width
23 mm
Number of channels
1
Power supply (AC/DC)
DC
Type of mounting
on awning profile
Height/depth
39 mm
IP degree of protection
44
Rated voltage
3 V
Dimensional drawing
Special features
NOT compatible with
Central Control CC41
Sensor functions
Sensor values - threshold settings
Tilt
Sensor values - evaluable
Tilt
Sensor values - detection
Tilt
Assembly and operating instructions
Declarations of conformity
Problem:
The awning retracts every hour, and can only be moved by holding the travel button down.
Remedy:
The awning retracts every hour, and can only be moved by holding the travel button down.
Remedy:
- Insert a new battery.
- Insert batteries correctly.
Problem:
The awning does not extend to the limit position and then retracts, despite calm conditions.
Remedy:
The awning does not extend to the limit position and then retracts, despite calm conditions.
Remedy:
- Vibration is detected when the awning is extending. Adjust the wind threshold on the master transmitter.
Problem:
Awning does not react to wind.
Remedy:
Awning does not react to wind.
Remedy:
- Program the SC211-2.
- Adjust the wind threshold on the transmitter.
Problem:
An increase or decrease in the angle of inclination is not detected.
Remedy:
An increase or decrease in the angle of inclination is not detected.
Remedy:
- The rotary switch for the release angle is set to "0". Set the release angle and program the initial angle of inclination.
Problem:
The awning extends and then immediately retracts once more every 15 minutes.
Remedy:
The awning extends and then immediately retracts once more every 15 minutes.
Remedy:
- There is a high wind and a high sunshine level at the same time. Deactivate the automatic sun protection
Problem:
The awning movement sensor has no assigned function.
Remedy:
The awning movement sensor has no assigned function.
Remedy:
- Ensure that the PCB is completely pushed in.