Usage recommendation
- Open/semi-open articulated-arm awning
- Articulated-arm cassette awning
Certifications
Product highlights
... For the user:
Blockage detection in both directions with automatic reversal and multiple testing
Optional activation: Fabric tensioning function
Higher closing force for cassette awnings
Fabric untensioning can be switched on/off in the upper limit position
Made in Germany - for maximum reliability and durability
... For installation:
Intelligent installation management permits limit position corrections
Automatic shading solution length adjustment
Switchable stop behaviour
Setting of limit positions via switch on the drive head without the need for a special programming unit
Setting limit positions: Automatic detection with existing upper stop and fixed point lower limit position programming
Limit positions status indicator (LSI) signals missing limit positions
Auto-install function
... For planning:
After operation in an emergency, the drive finds its limit positions again independently
Electronic limit switching
Supports parallel connection
C-Plug pluggable connecting cable
General product data
RRP (incl. VAT)
350,00 €
Designation
R20-17-E33
Drive diameter
Ø 45mm = R
Sales unit
pc.
Series
E33
Item number
2020 130 184 0
GTIN
4251852915929
Technical data
Duty cycle
S2 4 min
Colour
White (RAL 9016)
Weight
2.085 kg
Power supply (AC/DC)
Alternating current
Rated voltage
230 V
Power consump.
160 W
IP degree of protection
44
Rated current
0.7 A
Mains frequency
50 Hz
Speed (load)
14 U/min
Drive torque (Nm)
20 Nm
Speed (rpm)
17 U/min
Cable type
plug-in
Dimensions
Dimension L1
501.95 mm
Dimension L2
518.95 mm
Dimension L3
535.95 mm
Dimension L4
17 mm
Dimension L5
17 mm
Dimension Ø c
45 mm
Dimensional drawing
Drive adapter width from Drive adapter DW78 R+F diecast (4930 300 091 0), when selecting a different drive adapter, the dimensions L2, L3 and L5 will change
Special features
Suitable for connection in parallel
Motor head can be overwrapped
Obstacle detection
Blockage detection in both directions
Commissioning
Higher closing force can be set
Limit position programming
Intelligent installation management (3x approach)
LSI - limit positions status indicator
Additional features
Soft stop upper limit position
7-Stage - stage 5
Drive can be operated by wired operator control
Fabric untensioning - reversal at the retracted stop- factory default
Fabric untensioning - reversal at the retracted stop
5° - can be activated/deactivated at any time
Assembly and operating instructions
Miscellaneous
Problem:
Tubular drive overruns the limit position or stops short of the set limit position.
Remedy:
Tubular drive does not run in the right direction.
Remedy:
The tubular drive does not retract after setting the extended limit position.
Remedy:
Tubular drive overruns the limit position or stops short of the set limit position.
Remedy:
- Check electrical installation, remove external devices, delete limit positions and then reset limit positions.
- Repair electrical installation and re-program limit positions.
- Stops have broken off or one or several attachments are broken. Repair system; reset tubular drive, then re-program limit positions.
____________________________________________
____________________________________________
Tubular drive does not run in the right direction.
Remedy:
- Tubular drive is overheated. The tubular drive is operational again after a few minutes.
- Tubular drive is faulty (does not run even after standing still for a long period of time). Replace the tubular drive.
- Clear and remove the obstruction and switch in the desired direction. Check the electrical connection.
____________________________________________
The tubular drive does not retract after setting the extended limit position.
Remedy:
- Delete the limit positions, reprogram the outer limit position, and retract immediately.