Usage recommendation
Sun protection
Product highlights
Device can also be activated using the CentralControl
Gerät auch über die CentralControl ansteuerbar
Ideal for retrofitting wired sun protection system for radio-based sun and wind monitoring
Two intermediate positions can be programmed
Setting the threshold values possible via a programmed operating device
Control button directly on the device
Suitable for outdoor installation
Adjustable sensor foot for optimum mounting
Can be programmed to recognise up to 16 Centronic transmitters
General product data
Designation
Centronic SunWindControl SWC510
Item number
4033 000 022 0
RRP (incl. VAT)
292,00 €
Series
Sensors
GTIN
4251852908334
Sales unit
pc.
Technical data
Weight
0.669 kg
Dimensions
B x H x T: 150 x 190 x 50 mm
Mains frequency
50 Hz
Colour
Grey
Height/depth
50 mm
Power supply (AC/DC)
Alternating current
Width
150 mm
Type of mounting
Surface mounted
IP degree of protection
44
Switching current max.
µ 5A / 230V / AC cos Φ = 1
Number of channels
1
Length
190 mm
Can be integrated into the switch frame
no
Wall bracket included
Intermediate positions
2
Rated voltage
230 V
Dimensional drawing
Communication
Control modes
Sun protection
Radio frequency
868,3 MHz
Additional features
Intermediate positions
2
Sensor functions
Sensor values - evaluable
- Sun
- Wind
Sensor values - detection
- Wind
- Sun
Assembly and operating instructions
Declarations of conformity
Miscellaneous
Problem:
Drive is not functioning.
Remedy:
Drive is running in the wrong direction.
Remedy:
Automatic drive commands are not executed.
Remedy:
System does not extend automatically when slide switch is set to SUN.
Remedy:
The sensor does not perform the manual drive commands from a hand-held transmitter.
Remedy:
Drive is not functioning.
Remedy:
- Check the electrical connection.
____________________________________________
Drive is running in the wrong direction.
Remedy:
- Swap the drive wires for OPEN and CLOSE.
____________________________________________
Automatic drive commands are not executed.
Remedy:
- Set the slide switch on the manual/wall transmitter to SUN.
- Program transmitter.
____________________________________________
System does not extend automatically when slide switch is set to SUN.
Remedy:
- Adjust sun threshold value.
- Wind threshold value exceeded. Wait for the wind to die down.
Problem:
System does not extend manually when slide switch is set to SUN or MANUAL.
Remedy:
System does not extend manually when slide switch is set to SUN or MANUAL.
Remedy:
- Wind threshold value exceeded. Wait for the wind to die down.
____________________________________________
The sensor does not perform the manual drive commands from a hand-held transmitter.
Remedy:
- Program transmitter.
____________________________________________