Usage recommendation
Lighting
Product highlights
Integration into Becker CentralControl possible
Compatible with homee smart home system
Two memory switching times with daily repetition programmable
Compatible with Centronic und CentronicPlus transmitters and sensors
The device feeds its position or switching state and status information back to the operator unit and gateway
Mesh technology ensures the automatic networking of all devices to create a powerful network
External one-way button can be connected
Any switch-button can be connected
Can be fitted into any flush-mounted device socket with 58 mm diameter according to DIN EN 49073 / DIN EN 60670
Installation behind the operator control in any deep flush-mounted switch box possible
Can be combined with any switch range
Can be programmed to recognise up to 16 Centronic transmitters
General product data
Sales unit
pc.
Item number
4036 000 014 0
Series
Receiver
RRP (incl. VAT)
137,00 €
GTIN
4251852916483
Designation
Centronic LightControl LC120 PLUS
Technical data
An external switch/pushbutton can be connected
Power supply (AC/DC)
Alternating current
Dimensions
B x H x T: 40 x 42 x 20 mm
Switching current max.
µ 3A / 110-240V / AC cos Φ = 1
Number of channels
2
Colour
Grey
Width
40 mm
Can be integrated into the switch frame
no
Type of mounting
Flush mounted
IP degree of protection
20
Pulse output
1s
Length
42.5 mm
Weight
0.159 kg
Height/depth
19.5 mm
Mains frequency
50 Hz
Rated voltage
110 - 240 V
Dimensional drawing
Communication
Bidirectional product
Active participant for routing/meshing
Additional features
Time function
Memory
Time function
Time function
Memory
Assembly and operating instructions
Declarations of conformity
Miscellaneous
Problem:
Tubular drive/receiver is not responding.
Remedy:
- Insert a new battery/batteries into the hand-held transmitter.
- Make sure the battery/batteries is/are correctly inserted in the hand-held transmitter.
- Reduce distance from receiver.
- Program transmitter.
- Check the receiver.
____________________________________________
Problem:
The LED ring on the hand-held transmitter lights up red when the receiver for the setting mode is selected.
Remedy:
- Reduce distance from receiver.
- Check electr. connection of the receiver.
- Put the receiver into programming mode.
- Add the transmitter to the installation.
____________________________________________
Set switching times change.
Remedy:
- Frequent 230 V AC power cuts. Fluctuations in the 50 Hz mains frequency.
Use a "TimeControl" transmitter and adjust the desired switching time there.
Problem:
The required setting cannot be changed.
Remedy:
- Make sure that the CentronicPlus transmitter is in setting mode if necessary.
____________________________________________
Required tubular drive/receiver is not responding.
Remedy:
- Program transmitter.
- Select the correct channel on the transmitter.
- Check connection.
- Check the external push-button connection.
____________________________________________
LED ring flashes yellow or red 4 times.
Remedy:
- Insert new batteries into the transmitter.
____________________________________________
Receiver does not react at the set time.
Remedy:
- Switch from Manual to Auto.
- If the slide switch of a Centronic transmitter is already at AUTO, it will need to be switched to MANUAL and then back to AUTO.
____________________________________________
This may also interest you!