Usage recommendation
Roller door
Product highlights
Integration into Becker CentralControl possible
Reverse travel on detection of an obstacle
Parameterisable inputs and outputs
Control button directly on the device
Complete with receiver and antenna
Operation of any 230 V door drives with pulse input
Two safety inputs present
Adjustable excess current shut-off
An additional operator control can be connected
Outdoor light can be connected
230 V light barrier can be connected
Electrical or optical safety contact edges can be connected
PW safety edges can be connected
Optional potential-free switching contact
Defined drive commands possible
Can be programmed to recognise up to 27 Centronic hand-held transmitter buttons
In plastic housing
General product data
RRP (incl. VAT)
319,00 €
Series
BOT
Sales unit
pc.
GTIN
4251852900437
Item number
4005 000 201 0
Designation
Beck-O-Tronic 6 Centronic
Technical data
Dimensions
B x H x T: 130 x 155 x 50 mm
Weight
0.6 kg
Type of mounting
Surface mounted
Width
130 mm
Number of channels
1
IP degree of protection
54
Switching current max.
500 VA / 250 VA
Height/depth
50 mm
Power supply (AC/DC)
Alternating current
Mains frequency
50 Hz
Included in delivery
Centronic EasyControl EC141-II
An external switch/pushbutton can be connected
Length
155 mm
Colour
Grey
Can be integrated into the switch frame
no
Rated voltage
230 V
Assembly and operating instructions
Declarations of conformity
Miscellaneous
Problem:
Error no. 01 Eeprom data.
Remedy:
Error no. 01 Eeprom data.
Remedy:
- Switch off operating voltage, wait 10 s, switch operating voltage back on. If the error message persists, the saved menu parameters are no longer correct. The control unit must be reset (item Reset / factory setting) and readjusted.
Problem:
Error no. 02 Motor current detection.
Remedy:
Error no. 02 Motor current detection.
Remedy:
- Switch off operating voltage, wait 10 s, switch operating voltage back on. If the error message persists, the motor current detection is faulty. The control unit must be replaced.
Error no. 03 N-relay cutoff.
Remedy:
Remedy:
- Switch off operating voltage, wait 10 s, switch operating voltage back on. If the error message persists, a short-circuit has occurred in the N-relay. The control unit must be replaced.
Error no. 04 OPEN/CLOSE relay cutoff.
Remedy:
Problem:Remedy:
- Switch off operating voltage, wait 10 s, switch operating voltage back on. If the error message persists, a short-circuit has occurred in the OPEN or CLOSE relay. The control unit must be replaced.
Error no. 05 Watchdog test.
Remedy:
Problem:
Error no. 06 ROM test.
Remedy:
Remedy:
- Switch off operating voltage, wait 10 s, switch operating voltage back on. If the error message persists, there is an error in the control unit hardware. The control unit must be replaced.
Problem:
Error no. 06 ROM test.
Remedy:
- Switch off operating voltage, wait 10 s, switch operating voltage back on. If the error message persists, there is an error in the controller hardware. The control unit must be replaced.
Problem:
Error no. 07 RAM test.
Remedy:
Problem:Error no. 07 RAM test.
Remedy:
- Switch off operating voltage, wait 10 s, switch operating voltage back on. If the error message persists, there is an error in the controller hardware. The control unit must be replaced.
Error no. 08 LS / SE1 (internal testing)
Remedy:
Remedy:
- Switch off operating voltage, wait 10 s, switch operating voltage back on. If the error message persists:
- a) Check setting [M.A2] when the closing edge safety device is connected.
- b) Check connection of the closing edge safety device, especially earth connection at terminal [Kl.14].
- c) If a) and b) are correct, an error possibly exists in the control unit hardware. The control unit must be replaced. The door can be operated in emergency mode.
Problem:
Error no. 09 LS / SE2 (internal testing)
Remedy:
Error no. 09 LS / SE2 (internal testing)
Remedy:
- Switch off operating voltage, wait 10 s, switch operating voltage back on. If the error message persists:
- a) Check setting [M.A4] with regard to connected closing edge safety device.
- b) Check connection of the closing edge safety device, especially earth connection at terminal [Kl.14].
- c) If a) and b) are correct, an error possibly exists in the control unit hardware. The control unit must be replaced. The door can be operated in emergency mode.
Problem:
Error no. 10 LS / SE1 (external testing).
Remedy:
Error no. 10 LS / SE1 (external testing).
Remedy:
- Switch off operating voltage, wait 10 s, switch operating voltage back on. If the error message persists:
- a) Check setting [M.A2] (external LS test) with regard to connected light barrier.
- b) Check connection of LS transmitter in accordance with item Safety input SE1 (LS / 1k2 / 8K2 / OSE).
- c) If a) and b) are correct, an error possibly exists in the control unit hardware. The control unit must be replaced. The door can be operated in emergency mode.
Error no. 20 SE1.
Remedy:
Problem:Remedy:
- The last door operation was stopped via an SE1 command.
Error no. 21 SE2.
Remedy:
Remedy:
- The last door operation was stopped via an SE2 command.
Problem:
Error no. 22 EMERGENCY STOP
Remedy:
Error no. 22 EMERGENCY STOP
Remedy:
- The last door operation was stopped via an EMERGENCY STOP command.
Problem:
Error no. 23 Prelimit switch.
Remedy:
Error no. 23 Prelimit switch.
Remedy:
- The pre-limit switch was actuated without SE1 being actuated within 2 s.
____________________________________________
Accessories for this item