Usage recommendation
- Articulated-arm cassette awning
- Open/semi-open articulated-arm awning
Certifications
Product highlights
... For the user:
Blockage detection in both directions with automatic reversal and multiple testing
Compatible with sun/wind/rain sensors for maximum convenience
Optional activation: Fabric tensioning function
Higher closing force for cassette awnings
Enables programming of 2 freely selectable intermediate positions
Made in Germany - for maximum reliability and durability
Fabric untensioning can be switched on/off in the upper limit position
... For installation:
Auto-install function
Setting limit positions: Automatic detection with existing upper stop and fixed point lower limit position programming
Intelligent installation management permits limit position corrections
Limit positions status indicator (LSI) signals missing limit positions
Convenient threshold adjustment via the hand-held transmitter or central control units
Switch on the motor head to change the direction of rotation and to activate and deactivate programming mode
Automatic shading solution length adjustment
Switchable stop behaviour
... For planning:
Supports parallel connection
Individual, group and central control possible (also by radio)
C-Plug pluggable connecting cable
Integrated radio receiver compatible with the Centronic control unit range
After operation in an emergency, the drive finds its limit positions again independently
Local operation with a standard single button
General product data
Series
C33
Designation
R40-17-C33
Item number
2040 130 191 0
GTIN
4251852916216
Sales unit
pc.
RRP (incl. VAT)
482,00 €
Drive diameter
Ø 45mm = R
Technical data
Weight
2.9 kg
IP degree of protection
44
Mains frequency
50 Hz
Colour
White (RAL 9016)
Speed (load)
14 U/min
Rated current
1.15 A
Power consump.
260 W
Power supply (AC/DC)
Alternating current
Rated voltage
230 V
Intermediate positions
2
Duty cycle
S2 4 min
Drive torque (Nm)
40 Nm
Speed (rpm)
17 U/min
Cable type
plug-in
Dimensions
Dimension L1
540.3 mm
Dimension L2
557.3 mm
Dimension L3
574.3 mm
Dimension L4
17 mm
Dimension L5
17 mm
Dimension Ø c
45 mm
Drive adapter width from Drive adapter DW78 R+F diecast (4930 300 091 0), when selecting a different drive adapter, the dimensions L2, L3 and L5 will change
Special features
Suitable for connection in parallel
Motor head can be overwrapped
Communication
Radio compatibility
Centronic
Obstacle detection
Blockage detection in both directions
Commissioning
Higher closing force can be set
Limit position programming
Intelligent installation management (3x approach)
LSI - limit positions status indicator
Additional features
Intermediate positions
2
Soft stop upper limit position
7-Stage - stage 5
Drive can be operated by wired operator control
Fabric untensioning - reversal at the retracted stop- factory default
Fabric untensioning - reversal at the retracted stop
5° - can be activated/deactivated at any time
Sensor functions
Sensor values - evaluable
- Wind
- Rain
- Sun
Assembly and operating instructions
Declarations of conformity
Miscellaneous
selected item
Tubular drive does not run in the right direction.
Remedy:
Problem:
Drive is not functioning.
Remedy:
Problem:
Incorrect running direction after deleting limit positions.
Remedy:
Problem:
Setting the limit positions using Auto-install does not work.
Remedy:
Problem:
Awning cannot be extended or retracted with the emergency crank (when using the drive adapter for applications with separate emergency crank).
Remedy:
____________________________________________
Tubular drive does not run in the right direction.
Remedy:
- Tubular drive is overheated. The tubular drive is operational again after a few minutes.
- Tubular drive is faulty (does not run even after standing still for a long period of time). Replace the tubular drive.
- Clear and remove the obstruction and switch in the desired direction. Check the electrical connection.
____________________________________________
Problem:
Drive is not functioning.
Remedy:
- Program new transmitter.
- Bring transmitter within range of the tubular drive.
- Press drive or stop button on transmitter at least five times in the immediate vicinity of the tubular drive.
- Insert battery/batteries correctly in the transmitter or insert new battery/batteries.
- Check electrical connection.
- Thermal protection switch in tubular drive has tripped. Wait until the thermal protection switch in the tubular drive is reactivated.
Problem:
Running direction on tubular drive cannot be set
Remedy:
Running direction on tubular drive cannot be set
Remedy:
- Delete limit positions and reset the running direction.
____________________________________________
Problem:
Incorrect running direction after deleting limit positions.
Remedy:
- Use the master transmitter or the direction switch on the tubular drive to change the direction of rotation.
____________________________________________
Problem:
Setting the limit positions using Auto-install does not work.
Remedy:
- Move to the desired extended limit position and set a point.
____________________________________________
Problem:
Awning cannot be extended or retracted with the emergency crank (when using the drive adapter for applications with separate emergency crank).
Remedy:
- Check that the drive adapter is assembled correctly.
____________________________________________
* C-plug connecting cables are available in various versions and lengths and must be ordered separately.
Accessories for this item