Usage recommendation
- Volants
- Conservatory awning
- Articulated-arm cassette awning
- Markisolette/window awning
- Pergola
- Guided
- Open/semi-open articulated-arm awning
- Horizontal screen
- Drop-arm awning
Certifications
Product highlights
... For the user:
Enables programming of 2 freely selectable intermediate positions
Optional activation: Fabric tensioning function
Made in Germany - for maximum reliability and durability
Fabric untensioning can be switched on/off in the upper limit position
Higher closing force for cassette awnings
Blockage detection in both directions with automatic reversal and multiple testing
Compatible with sun/wind/rain sensors for maximum convenience
... For installation:
Lower limit position adjustment: point (automatic detection or freely programmable), Upper limit position adjustment: point or stop
Intelligent installation management permits limit position corrections
Convenient threshold adjustment via the hand-held transmitter or central control units
Automatic shading solution length adjustment
Auto-install function
Switchable stop behaviour
Switch on the motor head to change the direction of rotation and to activate and deactivate programming mode
Limit positions status indicator (LSI) signals missing limit positions
... For planning:
Integrated radio receiver compatible with the Centronic control unit range
Local operation with a standard single button
C-Plug pluggable connecting cable
Supports parallel connection
Individual, group and central control possible (also by radio)
General product data
Designation
P5-30-C12
Drive diameter
Ø 35mm = P
RRP (incl. VAT)
396,00 €
Series
C12
Item number
2009 130 118 0
Sales unit
pc.
GTIN
4251852905289
Technical data
Power consump.
110 W
Power supply (AC/DC)
Alternating current
Rated current
0.45 A
Rated voltage
230 V
Mains frequency
50 Hz
Colour
White (RAL 9016)
Weight
1.102 kg
IP degree of protection
44
Duty cycle
S2 4 min
Intermediate positions
2
Speed (load)
23 U/min
Drive torque (Nm)
5 Nm
Speed (rpm)
30 U/min
Cable type
plug-in
Dimensions
Dimension L1
453 mm
Dimension L2
470 mm
Dimension L3
483 mm
Dimension L4
13 mm
Dimension L5
17 mm
Dimension Ø c
35 mm
Dimensional drawing
Drive adapter width from Drive adapter 40 x 1/42 x 2 (4930 300 086 0), when selecting a different drive adapter, the dimensions L2, L3 and L5 will change
Special features
Suitable for connection in parallel
Motor head can be overwrapped
Communication
Radio compatibility
Centronic
Obstacle detection
Blockage detection in both directions
Commissioning
Reduced drive torque during installation
Higher closing force can be set
Limit position programming
Intelligent installation management (3x approach)
LSI - limit positions status indicator
Additional features
Intermediate positions
2
Soft stop upper limit position
7-Stage - stage 5
Drive can be operated by wired operator control
Fabric untensioning - reversal at the retracted stop
5° - can be activated/deactivated at any time
Sensor functions
Sensor values - evaluable
- Wind
- Rain
- Sun
Assembly and operating instructions
Miscellaneous
selected item
Tubular drive does not run in the right direction.
Remedy:
Problem:
Drive is not functioning.
Remedy:
Problem:
Incorrect running direction after deleting limit positions.
Remedy:
____________________________________________
Tubular drive does not run in the right direction.
Remedy:
- Tubular drive is overheated. The tubular drive is operational again after a few minutes.
- Tubular drive is faulty (does not run even after standing still for a long period of time). Replace the tubular drive.
- Clear and remove the obstruction and switch in the desired direction. Check the electrical connection.
____________________________________________
Problem:
Drive is not functioning.
Remedy:
- Program new transmitter.
- Bring transmitter within range of the tubular drive.
- Press drive or stop button on transmitter at least five times in the immediate vicinity of the tubular drive.
- Insert battery/batteries correctly in the transmitter or insert new battery/batteries.
- Check electrical connection.
- Thermal protection switch in tubular drive has tripped. Wait until the thermal protection switch in the tubular drive is reactivated.
Problem:
Running direction on tubular drive cannot be set
Remedy:
Running direction on tubular drive cannot be set
Remedy:
- Delete limit positions and reset the running direction.
____________________________________________
Problem:
Incorrect running direction after deleting limit positions.
Remedy:
- Use the master transmitter or the direction switch on the tubular drive to change the direction of rotation.
____________________________________________
* C-plug connecting cables are available in various versions and lengths and must be ordered separately.