Usage recommendation
Sun protection systems with locking mechanism
Certifications
Product highlights
... For the user:
Fabric untensioning can be switched on/off in the upper limit position
Blockage detection in the UP direction (anti-freeze mechanism)
Made in Germany - for maximum reliability and durability
Compatible with sun/wind/rain sensors for maximum convenience
Optional activation: Fabric tensioning function
Enables programming of 2 freely selectable intermediate positions
Memory function: Integrated timer can be activated via MemoControl transmitter
... For installation:
Switch on the motor head to change the direction of rotation and to activate and deactivate programming mode
Automatic shading solution length adjustment
Convenient threshold adjustment via the hand-held transmitter or central control units
Limit positions status indicator (LSI) signals missing limit positions
Intelligent installation management permits limit position corrections
Setting limit positions: Automatic detection with existing upper stop and fixed point lower limit position programming
... For planning:
C-Plug pluggable connecting cable
Integrated radio receiver compatible with the Centronic control unit range
For locking systems: The drive locks and unlocks automatically in the lower limit position
Local operation with a standard single button
Individual, group and central control possible (also by radio)
Supports parallel connection
General product data
Series
C16
Designation
L50-17-C16
Item number
2050 130 209 0
GTIN
4251852906118
Sales unit
pc.
RRP (incl. VAT)
551,00 €
Drive diameter
Ø 58mm = L
Technical data
Weight
4.36 kg
IP degree of protection
44
Mains frequency
50 Hz
Colour
White (RAL 9016)
Speed (load)
14 U/min
Rated current
1.4 A
Power consump.
315 W
Power supply (AC/DC)
Alternating current
Rated voltage
230 V
Intermediate positions
1
Duty cycle
S2 4 min
Drive torque (Nm)
50 Nm
Speed (rpm)
17 U/min
Cable type
plug-in
Dimensions
Dimension L1
557 mm
Dimension L2
587 mm
Dimension L3
608.3 mm
Dimension L4
20 mm
Dimension L5
30 mm
Dimension Ø c
58 mm
Dimensional drawing
Drive adapter width from Drive adapter DW78N 1.5 mm centre offset (4931 300 365 0), when selecting a different drive adapter, the dimensions L2, L3 and L5 will change
Special features
Suitable for connection in parallel
Motor head can be overwrapped
Communication
Radio compatibility
Centronic
Obstacle detection
Blockage detection in both directions
Limit position programming
Intelligent installation management (3x approach)
LSI - limit positions status indicator
Additional features
Intermediate positions
1
Soft stop upper limit position
7-Stage - stage 5
Time function
Memory
Drive can be operated by wired operator control
Fabric untensioning - reversal at the retracted stop
5° - can be activated/deactivated at any time
Sensor functions
Sensor values - evaluable
- Wind
- Sun
- Rain
Time function
Time function
Memory
Assembly and operating instructions
Miscellaneous
selected item
Tubular drive does not run in the right direction.
Remedy:
Problem:
Drive is not functioning.
Remedy:
Problem:
Incorrect running direction after deleting limit positions.
Remedy:
Problem:
Tubular drive is not locking. Tubular drive automatically approaches the locking point 3 times.
Remedy:
____________________________________________
Tubular drive does not run in the right direction.
Remedy:
- Tubular drive is overheated. The tubular drive is operational again after a few minutes.
- Tubular drive is faulty (does not run even after standing still for a long period of time). Replace the tubular drive.
- Clear and remove the obstruction and switch in the desired direction. Check the electrical connection.
____________________________________________
Problem:
Drive is not functioning.
Remedy:
- Program new transmitter.
- Bring transmitter within range of the tubular drive.
- Press drive or stop button on transmitter at least five times in the immediate vicinity of the tubular drive.
- Insert battery/batteries correctly in the transmitter or insert new battery/batteries.
- Check electrical connection.
- Thermal protection switch in tubular drive has tripped. Wait until the thermal protection switch in the tubular drive is reactivated.
Problem:
Running direction on tubular drive cannot be set
Remedy:
Running direction on tubular drive cannot be set
Remedy:
- Delete limit positions and reset the running direction.
____________________________________________
Problem:
Incorrect running direction after deleting limit positions.
Remedy:
- Use the master transmitter or the direction switch on the tubular drive to change the direction of rotation.
____________________________________________
Problem:
Tubular drive is not locking. Tubular drive automatically approaches the locking point 3 times.
Remedy:
- The locking point is not correctly programmed. Re-program limit positions.
Problem:
Tubular drive is not unlocking. Tubular drive automatically approaches the unlocking point 5 times.
Remedy:
Tubular drive is not unlocking. Tubular drive automatically approaches the unlocking point 5 times.
Remedy:
- The unlocking point is not correctly programmed. Re-program limit positions.
____________________________________________
* C-plug connecting cables are available in various versions and lengths and must be ordered separately.