Usage recommendation
Sun protection systems with locking mechanism
Certifications
Product highlights
... For the user:
Compatible with sun/wind/rain sensors for maximum convenience
Made in Germany - for maximum reliability and durability
Optional activation: Fabric tensioning function
Memory function: Integrated timer can be activated via MemoControl transmitter
Enables programming of 2 freely selectable intermediate positions
Blockage detection in the UP direction (anti-freeze mechanism)
Fabric untensioning can be switched on/off in the upper limit position
... For installation:
Limit positions status indicator (LSI) signals missing limit positions
Intelligent installation management permits limit position corrections
Switch on the motor head to change the direction of rotation and to activate and deactivate programming mode
Setting limit positions: Automatic detection with existing upper stop and fixed point lower limit position programming
Automatic shading solution length adjustment
Convenient threshold adjustment via the hand-held transmitter or central control units
... For planning:
For locking systems: The drive locks and unlocks automatically in the lower limit position
C-Plug pluggable connecting cable
Local operation with a standard single button
Integrated radio receiver compatible with the Centronic control unit range
Individual, group and central control possible (also by radio)
Supports parallel connection
General product data
GTIN
4251852906170
Series
C16
Sales unit
pc.
Designation
L100-11-C16
Drive diameter
Ø 58mm = L
RRP (incl. VAT)
649,00 €
Item number
2100 130 105 0
Technical data
Rated voltage
230 V
Power consump.
396 W
Power supply (AC/DC)
Alternating current
Rated current
1.7 A
Speed (load)
8 U/min
IP degree of protection
44
Colour
White (RAL 9016)
Mains frequency
50 Hz
Intermediate positions
1
Duty cycle
S2 4 min
Weight
5.025 kg
Drive torque (Nm)
100 Nm
Speed (rpm)
11 U/min
Cable type
plug-in
Dimensions
Dimension L1
587.55 mm
Dimension L2
617.55 mm
Dimension L3
638.85 mm
Dimension L4
20 mm
Dimension L5
30 mm
Dimension Ø c
58 mm
Dimensional drawing
Drive adapter width from Drive adapter DW78N 1.5 mm centre offset (4931 300 365 0), when selecting a different drive adapter, the dimensions L2, L3 and L5 will change
Special features
Suitable for connection in parallel
Motor head can be overwrapped
Communication
Radio compatibility
Centronic
Obstacle detection
Blockage detection in both directions
Limit position programming
Intelligent installation management (3x approach)
LSI - limit positions status indicator
Additional features
Intermediate positions
1
Soft stop upper limit position
7-Stage - stage 5
Time function
Memory
Drive can be operated by wired operator control
Fabric untensioning - reversal at the retracted stop
5° - can be activated/deactivated at any time
Sensor functions
Sensor values - evaluable
- Sun
- Rain
- Wind
Time function
Time function
Memory
Assembly and operating instructions
Miscellaneous
selected item
Tubular drive does not run in the right direction.
Remedy:
Problem:
Drive is not functioning.
Remedy:
Problem:
Incorrect running direction after deleting limit positions.
Remedy:
Problem:
Tubular drive is not locking. Tubular drive automatically approaches the locking point 3 times.
Remedy:
____________________________________________
Tubular drive does not run in the right direction.
Remedy:
- Tubular drive is overheated. The tubular drive is operational again after a few minutes.
- Tubular drive is faulty (does not run even after standing still for a long period of time). Replace the tubular drive.
- Clear and remove the obstruction and switch in the desired direction. Check the electrical connection.
____________________________________________
Problem:
Drive is not functioning.
Remedy:
- Program new transmitter.
- Bring transmitter within range of the tubular drive.
- Press drive or stop button on transmitter at least five times in the immediate vicinity of the tubular drive.
- Insert battery/batteries correctly in the transmitter or insert new battery/batteries.
- Check electrical connection.
- Thermal protection switch in tubular drive has tripped. Wait until the thermal protection switch in the tubular drive is reactivated.
Problem:
Running direction on tubular drive cannot be set
Remedy:
Running direction on tubular drive cannot be set
Remedy:
- Delete limit positions and reset the running direction.
____________________________________________
Problem:
Incorrect running direction after deleting limit positions.
Remedy:
- Use the master transmitter or the direction switch on the tubular drive to change the direction of rotation.
____________________________________________
Problem:
Tubular drive is not locking. Tubular drive automatically approaches the locking point 3 times.
Remedy:
- The locking point is not correctly programmed. Re-program limit positions.
Problem:
Tubular drive is not unlocking. Tubular drive automatically approaches the unlocking point 5 times.
Remedy:
Tubular drive is not unlocking. Tubular drive automatically approaches the unlocking point 5 times.
Remedy:
- The unlocking point is not correctly programmed. Re-program limit positions.
____________________________________________
* C-plug connecting cables are available in various versions and lengths and must be ordered separately.