Usage recommendation
Sun protection systems with locking mechanism
Certifications
Product highlights
... For the user:
Blockage detection in the UP direction (anti-freeze mechanism)
Made in Germany - for maximum reliability and durability
Optional activation: Fabric tensioning function
Fabric untensioning can be switched on/off in the upper limit position
... For installation:
Intelligent installation management permits limit position corrections
Setting limit positions: Automatic detection with existing upper stop and fixed point lower limit position programming
Automatic shading solution length adjustment
Limit positions status indicator (LSI) signals missing limit positions
... For planning:
Electronic limit switching
For locking systems: The drive locks and unlocks automatically in the lower limit position
C-Plug pluggable connecting cable
Supports parallel connection
General product data
Series
E16
RRP (incl. VAT)
327,00 €
Drive diameter
Ø 45mm = R
GTIN
4251852904527
Sales unit
pc.
Designation
R12-17-E16
Item number
2010 130 178 0
Technical data
Rated current
0.5 A
Duty cycle
S2 4 min
Power consump.
110 W
Mains frequency
50 Hz
Power supply (AC/DC)
Alternating current
Rated voltage
230 V
Speed (load)
14 U/min
IP degree of protection
44
Colour
White (RAL 9016)
Weight
1.9 kg
Drive torque (Nm)
12 Nm
Speed (rpm)
17 U/min
Cable type
plug-in
Dimensions
Dimension L1
472.6 mm
Dimension L2
489.6 mm
Dimension L3
506.6 mm
Dimension L4
17 mm
Dimension L5
17 mm
Dimension Ø c
45 mm
Dimensional drawing
Drive adapter width from Drive adapter DW78 R+F diecast (4930 300 091 0), when selecting a different drive adapter, the dimensions L2, L3 and L5 will change
Special features
Suitable for connection in parallel
Motor head can be overwrapped
Obstacle detection
Blockage detection in both directions
Limit position programming
Intelligent installation management (3x approach)
LSI - limit positions status indicator
Additional features
Soft stop upper limit position
7-Stage - stage 5
Drive can be operated by wired operator control
Fabric untensioning - reversal at the retracted stop
5° - can be activated/deactivated at any time
Assembly and operating instructions
Declarations of conformity
Miscellaneous
Problem:
Tubular drive overruns the limit position or stops short of the set limit position.
Remedy:
Tubular drive does not run in the right direction.
Remedy:
Problem:
Tubular drive only runs for approx. 1 second.
Remedy:
Tubular drive overruns the limit position or stops short of the set limit position.
Remedy:
- Check electrical installation, remove external devices, delete limit positions and then reset limit positions.
- Repair electrical installation and re-program limit positions.
- Stops have broken off or one or several attachments are broken. Repair system; reset tubular drive, then re-program limit positions.
____________________________________________
____________________________________________
Tubular drive does not run in the right direction.
Remedy:
- Tubular drive is overheated. The tubular drive is operational again after a few minutes.
- Tubular drive is faulty (does not run even after standing still for a long period of time). Replace the tubular drive.
- Clear and remove the obstruction and switch in the desired direction. Check the electrical connection.
____________________________________________
Problem:
Tubular drive only runs for approx. 1 second.
Remedy:
- Tubular drive is faulty. Replace the tubular drive.
____________________________________________
* C-plug connecting cables are available in various versions and lengths and must be ordered separately.