Usage recommendation
- Insect protection
- Open/semi-open articulated-arm awning
- Drop-arm awning
- Articulated-arm cassette awning
- Horizontal screen
- Pergola
- Conservatory awning
- Volants
- Markisolette/window awning
- Guided
Certifications
Product highlights
... For the user:
Made in Germany - for maximum reliability and durability
Fabric untensioning can be switched on/off in the upper limit position
Higher closing force for cassette awnings
Optional activation: Fabric tensioning function
Blockage detection in both directions with automatic reversal and multiple testing
... For installation:
Setting of limit positions via switch on the drive head without the need for a special programming unit
Limit positions status indicator (LSI) signals missing limit positions
Automatic shading solution length adjustment
Switchable stop behaviour
Intelligent installation management permits limit position corrections
Lower limit position adjustment: point (automatic detection or freely programmable), Upper limit position adjustment: point or stop
Auto-install function
... For planning:
Electronic limit switching
C-Plug pluggable connecting cable
Supports parallel connection
General product data
RRP (incl. VAT)
436,00 €
Drive diameter
Ø 58mm = L
GTIN
4251852916117
Series
E12
Item number
2060 130 140 0
Sales unit
pc.
Designation
L60-11-E12
Technical data
Rated voltage
230 V
Mains frequency
50 Hz
Weight
4.0571 kg
Rated current
1.2 A
Duty cycle
S2 4 min
Speed (load)
8 U/min
Power consump.
265 W
IP degree of protection
44
Colour
White (RAL 9016)
Power supply (AC/DC)
Alternating current
Drive torque (Nm)
60 Nm
Speed (rpm)
11 U/min
Cable type
plug-in
Dimensions
Dimension L1
532.5 mm
Dimension L2
562.5 mm
Dimension L3
583.8 mm
Dimension L4
20 mm
Dimension L5
30 mm
Dimension Ø c
58 mm
Dimensional drawing
Drive adapter width from Drive adapter DW78N 1.5 mm centre offset (4931 300 365 0), when selecting a different drive adapter, the dimensions L2, L3 and L5 will change
Special features
Suitable for connection in parallel
Motor head can be overwrapped
Obstacle detection
Blockage detection in both directions
Commissioning
Higher closing force can be set
Limit position programming
Intelligent installation management (3x approach)
LSI - limit positions status indicator
Additional features
Soft stop upper limit position
7-Stage - stage 5
Drive can be operated by wired operator control
Fabric untensioning - reversal at the retracted stop- factory default
Fabric untensioning - reversal at the retracted stop
5° - can be activated/deactivated at any time
Assembly and operating instructions
Miscellaneous
Problem:
Tubular drive overruns the limit position or stops short of the set limit position.
Remedy:
Tubular drive does not run in the right direction.
Remedy:
Problem:
Setting the limit positions using the programming unit does not work.
Remedy:
Problem:
Tubular drive switches off automatically before the first limit position is programmed.
Remedy:
Problem:
Setting the limit positions using Auto-install does not work.
Remedy:
Problem:
The stop behaviour cannot be changed.
Remedy:
Problem:
Tubular drive only runs for approx. 1 second.
Remedy:
Tubular drive overruns the limit position or stops short of the set limit position.
Remedy:
- Check electrical installation, remove external devices, delete limit positions and then reset limit positions.
- Repair electrical installation and re-program limit positions.
- Stops have broken off or one or several attachments are broken. Repair system; reset tubular drive, then re-program limit positions.
____________________________________________
____________________________________________
Tubular drive does not run in the right direction.
Remedy:
- Tubular drive is overheated. The tubular drive is operational again after a few minutes.
- Tubular drive is faulty (does not run even after standing still for a long period of time). Replace the tubular drive.
- Clear and remove the obstruction and switch in the desired direction. Check the electrical connection.
____________________________________________
Problem:
Setting the limit positions using the programming unit does not work.
Remedy:
- Set both switches to the delete setting.
- Execute a short drive command.
- Set both switches to the programming setting simultaneously.
- Re-set the limit positions using the programming unit.
Problem:
Setting the limit positions using the switch on the drive head does not work.
Remedy:
Setting the limit positions using the switch on the drive head does not work.
Remedy:
- Set both switches to the delete setting.
- Execute a short drive command.
- Re-set the limit positions.
____________________________________________
Problem:
Tubular drive switches off automatically before the first limit position is programmed.
Remedy:
- Tubular drive has detected a torque increase.
- Clear and remove the obstruction. Then move past this position to the desired limit position.
____________________________________________
Problem:
Setting the limit positions using Auto-install does not work.
Remedy:
- Move to the desired extended limit position and set a point.
____________________________________________
Problem:
The stop behaviour cannot be changed.
Remedy:
- Move to the stop limit position, and delete it individually using the programming unit. Move the system to a point between the limit positions. You can now change the stop behaviour.
____________________________________________
Problem:
Tubular drive only runs for approx. 1 second.
Remedy:
- Tubular drive is faulty. Replace the tubular drive.
____________________________________________
* C-plug connecting cables are available in various versions and lengths and must be ordered separately.