Usage recommendation
- Roller shutter
- Roller door
Certifications
Product highlights
... For the user:
Made in Germany - for maximum reliability and durability
... For installation:
Limit position adjustment: Automatic detection when fixed point end-positions at top/bottom are present
... For planning:
Crank can be inserted from 2 sides
Mechanical limit switching
General product data
RRP (incl. VAT)
1.052,00 €
Designation
L120-3-M07
Drive diameter
Ø 58mm = L
Sales unit
pc.
Series
M07
Item number
2120 060 002 0
GTIN
4251852901885
Technical data
Duty cycle
S2 8 min
Colour
White (RAL 9016)
Weight
5.93 kg
Power supply (AC/DC)
DC
Rated voltage
24 V
Power consump.
120 W
IP degree of protection
44
Rated current
5 A
Mains frequency
0 Hz
Speed (load)
3 U/min
Drive torque (Nm)
120 Nm
Speed (rpm)
4 U/min
Cable type
Rubber - S05RN-F 4x1 white
Cable length
4 m
Crank connection
Dimensions
Dimension L1
771.5 mm
Dimension L2
801.5 mm
Dimension L3
828.5 mm
Dimension L4
27 mm
Dimension L5
30 mm
Dimension Ø c
58 mm
Dimensional drawing
Drive adapter width from Drive adapter SM70 (4931 300 080 0), when selecting a different drive adapter, the dimensions L2, L3 and L5 will change
Special features
Crank connection
Additional features
Drive can be operated by wired operator control
Assembly and operating instructions
Declarations of conformity
Miscellaneous
Problem:
Tubular drive does not run in the right direction.
Remedy:
limit positions.
Stops have broken off or one or several attachments are broken. Repair system; delete limit positions,
re-program limit positions
Tubular drive does not run in the right direction.
Remedy:
Tubular drive does not run in the right direction.
Remedy:
- Tubular drive is overheated. The tubular drive is operational again after a few minutes.
- Tubular drive is faulty (does not run even after standing still for a long period of time). Replace the tubular drive.
- Clear and remove the obstruction and switch in the desired direction. Check the electrical connection.
____________________________________________
limit positions.
____________________________________________
Stops have broken off or one or several attachments are broken. Repair system; delete limit positions,
re-program limit positions
____________________________________________
Tubular drive does not run in the right direction.
Remedy:
- Tubular drive is overheated. The tubular drive is operational again after a few minutes.
- Tubular drive is faulty (does not run even after standing still for a long period of time). Replace the tubular drive.
- Clear and remove the obstruction and switch in the desired direction. Check the electrical connection.
____________________________________________