Usage recommendation
- Insect protection
- Roller shutter
- Projection screen
Certifications
Product highlights
... For the user:
Compatible with sun/wind/rain sensors for maximum convenience
Wireless software update via DECT central controls, e.g. FRITZ!Box
Fly screen protection function
Soft upper stop – optimum adaptation of closing forces for fabric protection
Sensitive obstacle detection in down direction for optimum protection of the application and the obstacle
Memory function: Integrated timer can be activated via MemoControl transmitter
The mesh technology allows individual drives to connect together automatically to form a very efficient network
Dynamic torque adjustment to accommodate changes in the roller shutter element
Upper anti-freeze mechanism with automatic shading solution length adjustment (can be additionally activated)
Blockage detection in the UP direction (anti-freeze mechanism)
Enables programming of 2 freely selectable intermediate positions
Automatic increase of the pressing force with anti-lifting devices
Made in Germany - for maximum reliability and durability
... For installation:
Limit position adjustment: Automatic detection when stop or fixed point end-positions are present
Automatic shading solution length adjustment
Limit positions status indicator (LSI) signals missing limit positions
Automatic detection of the limit positions when flexible suspension springs or rigid shaft connectors are used
Intelligent installation management permits limit position corrections
Convenient threshold adjustment via the hand-held transmitter or central control units
Switch on the motor head to change the direction of rotation and to activate and deactivate programming mode
... For planning:
Centronic radio receiver integrated: compatible with Centronic range of control units
Integrated radio receiver compatible with the Centronic control unit range
Individual, group and central control possible (also by radio)
Integrated CentronicPlus radio transceiver: Bidirectional, 868.3 MHz, the drive reports back its position, any blockage and other status information
Supports parallel connection
Integrated CentronicPlus radio transceiver: the drive reports back its position, any blockage and other status information
C-Plug pluggable connecting cable
Local operation with a standard single button
General product data
Designation
P5-16-C01 PLUS with bracket
Sales unit
pc.
Series
C01 PLUS
Item number
2009 120 116 0
RRP (incl. VAT)
361,00 €
GTIN
4251852900529
Drive diameter
Ø 35mm = P
Technical data
Weight
1.2 kg
Mains frequency
50 Hz
Power consump.
80 W
Rated current
0.35 A
Intermediate positions
2
Rated voltage
230 V
Power supply (AC/DC)
Alternating current
IP degree of protection
44
Duty cycle
S2 4 min
Colour
White (RAL 9016)
Speed (load)
13 U/min
Drive torque (Nm)
5 Nm
Speed (rpm)
16 U/min
Cable type
plug-in
Dimensions
Dimension L1
423 mm
Dimension L2
463 mm
Dimension L3
475 mm
Dimension L4
12 mm
Dimension L5
40 mm
Dimension Ø c
35 mm
Dimensional drawing
Drive adapter width from Drive adapter S40 for obstruction detection (4930 200 250 0), when selecting a different drive adapter, the dimensions L2, L3 and L5 will change
Special features
Suitable for connection in parallel
Motor head can be overwrapped
Communication
Bidirectional product
Active participant for routing/meshing
Radio compatibility
- Centronic PLUS
- Centronic
Obstacle detection
Obstruction detection, sensitive, in the extend direction (drive adapter)
- For roller shutters with rigid shaft connectors
- For roller shutters with springs
Blockage detection in both directions
Commissioning
Reduced drive torque during installation
Limit position programming
Intelligent installation management (3x approach)
Automatic detection of anti-lifting devices
LSI - limit positions status indicator
Fly screen and freeze protection function
Fly screen protection function
140° - can be activated/deactivated
Upper limit position anti-freeze mechanism/shading solution length adjustment
Travel specified - can be activated/deactivated
Additional features
Intermediate positions
2
Soft stop upper limit position
dynamic
Time function
Memory
Drive can be operated by wired operator control
Sensor functions
Sensor values - evaluable
- Twilight
- Rain
- Temperature
- Sun
- Wind
- Frost
Time function
Time function
Memory
Assembly and operating instructions
Miscellaneous
selected item
Tubular drive does not run in the right direction.
Remedy:
Problem:
Incorrect running direction after deleting limit positions.
Remedy:
Problem:
The LED ring lights up red when the receiver for the setting mode is selected.
Remedy:
Problem:
During the programming run, the drive stops short of the limit position to be programmed.
Remedy:
Problem:
Ventilation slots of the roller shutter do not close fully.
Remedy:
Problem:
Drive is not functioning.
Remedy:
Switching times cannot be set on tubular drive.
Remedy:
____________________________________________
Tubular drive does not run in the right direction.
Remedy:
- Tubular drive is overheated. The tubular drive is operational again after a few minutes.
- Tubular drive is faulty (does not run even after standing still for a long period of time). Replace the tubular drive.
- Clear and remove the obstruction and switch in the desired direction. Check the electrical connection.
____________________________________________
Problem:
Incorrect running direction after deleting limit positions.
Remedy:
- Use the relevant transmitter or the direction switch on the tubular drive to change the direction of rotation.
____________________________________________
Problem:
The LED ring lights up red when the receiver for the setting mode is selected.
Remedy:
- Reduce the distance from the receiver.
- Check the electrical connection of the receiver.
- Put the receiver into programming mode.
- Add the transmitter to the installation.
Problem:
The required setting cannot be changed.
Remedy:
The required setting cannot be changed.
Remedy:
- Make sure that the CentronicPlus transmitter is in programming mode.
____________________________________________
Problem:
During the programming run, the drive stops short of the limit position to be programmed.
Remedy:
- For safety reasons, the drive reacts sensitively to sluggishness during the programming run, in order to prevent damage. Briefly run roller shutter DOWN and then UP until you reach the upper limit position.
____________________________________________
Problem:
Ventilation slots of the roller shutter do not close fully.
Remedy:
- Delete the limit positions (see Deleting limit positions) and then set the limit positions as per to lower point (see chapter Setting the limit positions); in this case, set the lower limit position first (lower point) followed by the upper limit position.
____________________________________________
Problem:
Drive is not functioning.
Remedy:
- Program new transmitter.
- Bring transmitter within range of the tubular drive.
- Press drive or stop button on transmitter at least five times in the immediate vicinity of the tubular drive.
- Insert battery/batteries correctly in the transmitter or insert new battery/batteries.
- Check electrical connection.
- Thermal protection switch in tubular drive has tripped. Wait until the thermal protection switch in the tubular drive is reactivated.
Problem:
Running direction on tubular drive cannot be set
Remedy:
Running direction on tubular drive cannot be set
Remedy:
- Delete limit positions and reset the running direction.
____________________________________________
Switching times cannot be set on tubular drive.
Remedy:
- Use Centronic transmitter with Manual/Auto slide switch or a CentronicPlus transmitter.
Problem:
Tubular drive does not operate at the set switching time.
Remedy:
Tubular drive does not operate at the set switching time.
Remedy:
- Switch from Manual to Auto.
- If the slide switch of a Centronic transmitter is already at Auto, it will need to be switched to Manual and then back to Auto.
Problem:
Set switching times change.
Remedy:
Set switching times change.
Remedy:
- Frequent 230 V AC power cuts. Fluctuations in the 50 Hz mains frequency.
Use a "TimeControl" transmitter and adjust the desired switching time there.
____________________________________________
* C-plug connecting cables are available in various versions and lengths and must be ordered separately.