Usage recommendation
Roller shutter
Certifications
Product highlights
... For the user:
Upper anti-freeze mechanism with automatic shading solution length adjustment (can be additionally activated)
Made in Germany - for maximum reliability and durability
Dynamic torque adjustment to accommodate changes in the roller shutter element
Soft upper stop – optimum adaptation of closing forces for fabric protection
Sensitive obstacle detection in down direction for optimum protection of the application and the obstacle
Blockage detection in the UP direction (anti-freeze mechanism)
Automatic increase of the pressing force with anti-lifting devices
... For installation:
Limit positions status indicator (LSI) signals missing limit positions
Automatic shading solution length adjustment
Automatic detection of the limit positions when flexible suspension springs or rigid shaft connectors are used
Limit position adjustment: Automatic detection when stop or fixed point end-positions are present
Intelligent installation management permits limit position corrections
... For planning:
Electronic limit switching
Supports parallel connection
General product data
Drive diameter
Ø 45mm = R
Designation
R30-17-E03 5 m Connecting cable
GTIN
4251852902363
Item number
2030 120 123 0
Series
E03
Sales unit
pc.
RRP (incl. VAT)
309,00 €
Technical data
Weight
2.814 kg
Speed (load)
14 U/min
Rated current
0.9 A
Power consump.
210 W
Duty cycle
S2 4 min
Power supply (AC/DC)
Alternating current
Rated voltage
230 V
Mains frequency
50 Hz
Colour
White (RAL 9016)
IP degree of protection
44
Drive torque (Nm)
30 Nm
Speed (rpm)
17 U/min
Cable type
Rubber - S05RN-F4G0.75 - white
Cable length
5 m
Dimensions
Dimension L1
531.6 mm
Dimension L2
571.6 mm
Dimension L3
587.6 mm
Dimension L4
16 mm
Dimension L5
40 mm
Dimension Ø c
45 mm
Dimensional drawing
Drive adapter width from Drive adapter S60L (4930 300 466 0), when selecting a different drive adapter, the dimensions L2, L3 and L5 will change
Special features
Suitable for connection in parallel
Motor head can be overwrapped
Obstacle detection
Blockage detection in both directions
Commissioning
Reduced drive torque during installation
Limit position programming
Intelligent installation management (3x approach)
Automatic detection of anti-lifting devices
LSI - limit positions status indicator
Fly screen and freeze protection function
Upper limit position anti-freeze mechanism/shading solution length adjustment
Travel specified - can be activated/deactivated
Additional features
Soft stop upper limit position
dynamic
Drive can be operated by wired operator control
Assembly and operating instructions
Declarations of conformity
Miscellaneous
Problem:
Tubular drive overruns the limit position or stops short of the set limit position.
Remedy:
Tubular drive does not run in the right direction.
Remedy:
limit positions.
Problem:
When opening, the drive stops short of the programmed limit position.
Remedy:
Tubular drive overruns the limit position or stops short of the set limit position.
Remedy:
- Check electrical installation, remove external devices, delete limit positions and then reset limit positions.
- Repair electrical installation and re-program limit positions.
- Stops have broken off or one or several attachments are broken. Repair system; reset tubular drive, then re-program limit positions.
____________________________________________
____________________________________________
Tubular drive does not run in the right direction.
Remedy:
- Tubular drive is overheated. The tubular drive is operational again after a few minutes.
- Tubular drive is faulty (does not run even after standing still for a long period of time). Replace the tubular drive.
- Clear and remove the obstruction and switch in the desired direction. Check the electrical connection.
____________________________________________
limit positions.
____________________________________________
Problem:
When opening, the drive stops short of the programmed limit position.
Remedy:
- Upper anti-freeze mechanism is activated.
- The roller shutter only opens to the upper stop once every 32 times.
- Deactivate the upper anti-freeze mechanism.
____________________________________________