Usage recommendation
Roller shutter with Venetian blind function
Certifications
Product highlights
... For the user:
Dynamic torque adjustment to accommodate changes in the roller shutter element
Range of programmable driving profiles
Automatic increase of the pressing force with anti-lifting devices
Made in Germany - for maximum reliability and durability
Fly screen protection function
Ultra-quiet operation thanks to Evolution technology (brushless DC technology)
Blockage detection in the UP direction (anti-freeze mechanism)
Soft upper stop – optimum adaptation of closing forces for fabric protection
Sensitive obstacle detection in down direction for optimum protection of the application and the obstacle
Upper anti-freeze mechanism with automatic shading solution length adjustment (can be additionally activated)
... For installation:
Intelligent installation management permits limit position corrections
Limit positions status indicator (LSI) signals missing limit positions
Limit position adjustment: Automatic detection when stop or fixed point end-positions are present
Automatic detection of the limit positions when flexible suspension springs or rigid shaft connectors are used
Automatic shading solution length adjustment
... For planning:
Supports parallel connection
C-Plug pluggable connecting cable
Suitable for use with roller shutters with blind function
Electronic limit switching
Either the closed or Venetian blind position can be approached directly.
General product data
RRP (incl. VAT)
327,00 €
Series
EVO 20 RJ
GTIN
4251852902929
Sales unit
pc.
Item number
1020 120 005 0
Drive diameter
Ø 45mm = R
Designation
R20-14 EVO 20 RJ
Technical data
IP degree of protection
44
Power supply (AC/DC)
Alternating current
Rated current
0.55 A
Speed (load)
10 U/min
Duty cycle
S2 4 min
Rated voltage
230 V
Weight
1.674 kg
Power consump.
90 W
Mains frequency
50 Hz
Colour
White (RAL 9016)
Drive torque (Nm)
20 Nm
Speed (rpm)
14 U/min
Cable type
plug-in
Dimensions
Dimension L1
492.5 mm
Dimension L2
532.5 mm
Dimension L3
548.5 mm
Dimension L4
16 mm
Dimension L5
40 mm
Dimension Ø c
45 mm
Dimensional drawing
Drive adapter width from Drive adapter S60L (4930 300 466 0), when selecting a different drive adapter, the dimensions L2, L3 and L5 will change
Special features
Suitable for connection in parallel
Motor head can be overwrapped
Obstacle detection
Blockage detection in both directions
Limit position programming
Intelligent installation management (3x approach)
Automatic detection of anti-lifting devices
LSI - limit positions status indicator
Fly screen and freeze protection function
Fly screen protection function
140° - can be activated/deactivated
Upper limit position anti-freeze mechanism/shading solution length adjustment
Travel specified - can be activated/deactivated
Upper limit position anti-freeze mechanism/shading solution length adjustment - factory default
Additional features
Soft stop upper limit position
Adjustable speed and travel
Individually adjustable speeds for opening and closing movement
Range of programmable driving profiles
Drive can be operated by wired operator control
Assembly and operating instructions
Declarations of conformity
Miscellaneous
Problem:
Tubular drive overruns the limit position or stops short of the set limit position.
Remedy:
Tubular drive does not run in the right direction.
Remedy:
limit positions.
Problem:
Ventilation slots of the roller shutter do not close fully.
Remedy:
Problem:
When opening, the drive stops short of the programmed limit position.
Remedy:
Problem:
The tubular drive does not switch to slow travel in order to install the third limit position.
Remedy:
Tubular drive overruns the limit position or stops short of the set limit position.
Remedy:
- Check electrical installation, remove external devices, delete limit positions and then reset limit positions.
- Repair electrical installation and re-program limit positions.
- Stops have broken off or one or several attachments are broken. Repair system; reset tubular drive, then re-program limit positions.
____________________________________________
____________________________________________
Tubular drive does not run in the right direction.
Remedy:
- Tubular drive is overheated. The tubular drive is operational again after a few minutes.
- Tubular drive is faulty (does not run even after standing still for a long period of time). Replace the tubular drive.
- Clear and remove the obstruction and switch in the desired direction. Check the electrical connection.
____________________________________________
limit positions.
____________________________________________
Problem:
Ventilation slots of the roller shutter do not close fully.
Remedy:
- Delete the limit positions (see Deleting limit positions) and then set the limit positions as per to lower point (see chapter Setting the limit positions); in this case, set the lower limit position first (lower point) followed by the upper limit position.
____________________________________________
Problem:
When opening, the drive stops short of the programmed limit position.
Remedy:
- Upper anti-freeze mechanism is activated.
- The roller shutter only opens to the upper stop once every 32 times.
- Deactivate the upper anti-freeze mechanism.
____________________________________________
Problem:
The tubular drive does not switch to slow travel in order to install the third limit position.
Remedy:
- The installation of the 1st and/or 2nd limit position is not yet complete. The upper stop limit position must be approached three times.
Problem:
The tubular drive only travels slowly.
Remedy:
The tubular drive only travels slowly.
Remedy:
- Set the closed limit position (third limit position).