Usage recommendation
- Roller shutter
- Projection screen
Certifications
Product highlights
... For the user:
Automatic increase of the pressing force with anti-lifting devices
Soft upper stop – optimum adaptation of closing forces for fabric protection
Made in Germany - for maximum reliability and durability
Fly screen protection function
Enables programming of 2 freely selectable intermediate positions
Blockage detection in the UP direction (anti-freeze mechanism)
Upper anti-freeze mechanism with automatic shading solution length adjustment (can be additionally activated)
Dynamic torque adjustment to accommodate changes in the roller shutter element
Sensitive obstacle detection in down direction for optimum protection of the application and the obstacle
... For installation:
Automatic shading solution length adjustment
Limit positions status indicator (LSI) signals missing limit positions
Automatic detection of the limit positions when flexible suspension springs or rigid shaft connectors are used
Limit position adjustment: Automatic detection when stop or fixed point end-positions are present
Adjustable direction of rotation
Intelligent installation management permits limit position corrections
... For planning:
C-Plug pluggable connecting cable
Integrated SMI technology
Supports parallel connection
General product data
GTIN
4251852906910
Series
S01
Sales unit
pc.
Designation
R40-17-S01
Drive diameter
Ø 45mm = R
RRP (incl. VAT)
419,00 €
Item number
2040 120 502 0
Technical data
Rated voltage
230 V
Power consump.
260 W
Power supply (AC/DC)
Alternating current
Rated current
1.15 A
Speed (load)
14 U/min
IP degree of protection
44
Colour
White (RAL 9016)
Mains frequency
50 Hz
Intermediate positions
2
Duty cycle
S2 4 min
Weight
2.872 kg
Drive torque (Nm)
40 Nm
Speed (rpm)
17 U/min
Cable type
plug-in
Dimensions
Dimension L1
540.3 mm
Dimension L2
580.3 mm
Dimension L3
597.3 mm
Dimension L4
17 mm
Dimension L5
40 mm
Dimension Ø c
45 mm
Dimensional drawing
Drive adapter width from Drive adapter S60 for obstruction detection (4930 200 222 0), when selecting a different drive adapter, the dimensions L2, L3 and L5 will change
Special features
Suitable for connection in parallel
Motor head can be overwrapped
Communication
Bidirectional product
Obstacle detection
Obstruction detection, sensitive, in the extend direction (drive adapter)
- For roller shutters with springs
- For roller shutters with rigid shaft connectors
Blockage detection in both directions
Commissioning
Reduced drive torque during installation
Limit position programming
Intelligent installation management (3x approach)
Automatic detection of anti-lifting devices
LSI - limit positions status indicator
Fly screen and freeze protection function
Fly screen protection function
140° - can be activated/deactivated
Upper limit position anti-freeze mechanism/shading solution length adjustment
Travel specified - can be activated/deactivated
Upper limit position anti-freeze mechanism/shading solution length adjustment - factory default
Additional features
Intermediate positions
2
Soft stop upper limit position
dynamic
Assembly and operating instructions
Miscellaneous
Problem:
Tubular drive does not run in the right direction.
Remedy:
Tubular drive does not run in the right direction.
Remedy:
Tubular drive overruns the limit position or stops short of the set limit position.
Remedy:
Problem:
The tubular drive does not function correctly in SMI mode.
Remedy:
Problem:
During the programming run, the drive stops short of the limit position to be programmed.
Remedy:
Problem:
Ventilation slots of the roller shutter do not close fully.
Remedy:
Tubular drive does not run in the right direction.
Remedy:
- Tubular drive is overheated. The tubular drive is operational again after a few minutes.
- Tubular drive is faulty (does not run even after standing still for a long period of time). Replace the tubular drive.
- Clear and remove the obstruction and switch in the desired direction. Check the electrical connection.
____________________________________________
____________________________________________
Tubular drive does not run in the right direction.
Remedy:
- Tubular drive is overheated. The tubular drive is operational again after a few minutes.
- Tubular drive is faulty (does not run even after standing still for a long period of time). Replace the tubular drive.
- Clear and remove the obstruction and switch in the desired direction. Check the electrical connection.
____________________________________________
Tubular drive overruns the limit position or stops short of the set limit position.
Remedy:
- Check electrical installation, remove external devices, delete limit positions and then reset limit positions.
- Repair electrical installation and re-program limit positions.
- Stops have broken off or one or several attachments are broken. Repair system; reset tubular drive, then re-program limit positions.
____________________________________________
Problem:
The tubular drive does not function correctly in SMI mode.
Remedy:
- Check the electrical connection.
Problem:
In BUS mode, the tubular drive extends the sun protection device with retraction commands or retracts it with extension commands.
Remedy:
In BUS mode, the tubular drive extends the sun protection device with retraction commands or retracts it with extension commands.
Remedy:
- Disconnect the tubular drive from the SMI BUS. Delete the limit positions, switch the direction switch to the opposite position and test the direction of travel with the programming unit. Re-program the limit positions.
____________________________________________
Problem:
During the programming run, the drive stops short of the limit position to be programmed.
Remedy:
- For safety reasons, the drive reacts sensitively to sluggishness during the programming run, in order to prevent damage. Briefly run roller shutter DOWN and then UP until you reach the upper limit position.
____________________________________________
Problem:
Ventilation slots of the roller shutter do not close fully.
Remedy:
- Delete the limit positions (see Deleting limit positions) and then set the limit positions as per to lower point (see chapter Setting the limit positions); in this case, set the lower limit position first (lower point) followed by the upper limit position.
____________________________________________
* C-plug connecting cables are available in various versions and lengths and must be ordered separately.
Accessories for this item
This may also interest you!