Usage recommendation
- Venetian blind/shutter
- Sun protection
- Roller shutter
Product highlights
Two intermediate positions can be programmed
Blind mode: Exact adjustment of slat angle possible
Single, group or central control unit
Function between drive and group control unit switchable
Timers and sun protection controls can be integrated upstream
Large, easy-to-read display
Control button directly on the device
Changing between manual and automatic mode possible on the operating device directly
An additional operator control can be connected
Optional potential-free switching contact
Can be fitted into any flush-mounted device socket with 58 mm diameter according to DIN EN 49073 / DIN EN 60670
Adapter frame enables integration in various switch ranges
Defined drive commands possible
General product data
Series
Control units
Designation
Centronic UnitControl UC52
Item number
4031 000 001 0
GTIN
4251852907474
Sales unit
pc.
RRP (incl. VAT)
141,00 €
Technical data
Weight
0.255 kg
Dimensions
B x H x T: 85 x 85 x 52 mm
Length
85.4 mm
Type of mounting
Flush mounted
Power supply (AC/DC)
Alternating current
Number of channels
1
Touch mode
Mains frequency
50 Hz
Width
85.4 mm
IP degree of protection
20
Switching current max.
µ 5A / 230V / AC cos Φ = 1
Can be integrated into the switch frame
Centronic
Colour
White
Intermediate positions
2
Height/depth
52.2 mm
Rated voltage
230 V
Dimensional drawing
Special features
NOT compatible with
Surface-mounted housing V3 for EC62S/EC62P
Additional features
Intermediate positions
2
Sensor functions
Manual/automatic mode changeover
Assembly and operating instructions
Declarations of conformity
Miscellaneous
Problem:
Drive is not functioning.
Remedy:
Drive is running in the wrong direction.
Remedy:
The control unit does not carry out the external commands.
Remedy:
Drive is not functioning.
Remedy:
- Check the electrical connection.
____________________________________________
Drive is running in the wrong direction.
Remedy:
- Swap the drive wires for OPEN and CLOSE.
____________________________________________
The control unit does not carry out the external commands.
Remedy:
- Set the slide switch to Automatic.
- Wait for or cancel alarm signal.
____________________________________________