Usage recommendation
- Venetian blind/shutter
- Sun protection
- Roller shutter
Product highlights
Two intermediate positions can be programmed
Blind mode: Exact adjustment of slat angle possible
Single, group or central control unit
Function between drive and group control unit switchable
Timers and sun protection controls can be integrated upstream
Large, easy-to-read display
Control button directly on the device
Changing between manual and automatic mode possible on the operating device directly
An additional operator control can be connected
Optional potential-free switching contact
Can be fitted into any flush-mounted device socket with 58 mm diameter according to DIN EN 49073 / DIN EN 60670
Adapter frame enables integration in various switch ranges
Defined drive commands possible
General product data
GTIN
4251852907474
Series
Control units
Sales unit
pc.
Designation
Centronic UnitControl UC52
RRP (incl. VAT)
141,00 €
Item number
4031 000 001 0
Technical data
Colour
White
Height/depth
52.2 mm
IP degree of protection
20
Power supply (AC/DC)
Alternating current
Mains frequency
50 Hz
Can be integrated into the switch frame
Centronic
Length
85.4 mm
Type of mounting
Flush mounted
Intermediate positions
2
Number of channels
1
Switching current max.
µ 5A / 230V / AC cos Φ = 1
Dimensions
B x H x T: 85 x 85 x 52 mm
Width
85.4 mm
Weight
0.255 kg
Touch mode
Rated voltage
230 V
Dimensional drawing
Special features
NOT compatible with
Surface-mounted housing V3 for EC62S/EC62P
Additional features
Intermediate positions
2
Sensor functions
Manual/automatic mode changeover
Assembly and operating instructions
Declarations of conformity
Miscellaneous
Problem:
Drive is not functioning.
Remedy:
Drive is running in the wrong direction.
Remedy:
The control unit does not carry out the external commands.
Remedy:
Drive is not functioning.
Remedy:
- Check the electrical connection.
____________________________________________
Drive is running in the wrong direction.
Remedy:
- Swap the drive wires for OPEN and CLOSE.
____________________________________________
The control unit does not carry out the external commands.
Remedy:
- Set the slide switch to Automatic.
- Wait for or cancel alarm signal.
____________________________________________
Accessories for this item