Usage recommendation
Sun protection
Product highlights
Gerät auch über die CentralControl ansteuerbar
Ideal for retrofitting wired sun protection system for radio-based sun and wind monitoring
Two intermediate positions can be programmed
Setting the threshold values possible via a programmed operating device
Control button directly on the device
Suitable for outdoor installation
Adjustable sensor foot for optimum mounting
Can be programmed to recognise up to 16 Centronic transmitters
General product data
GTIN
4251852908334
Sales unit
pc.
Series
Sensors
RRP (incl. VAT)
292,00 €
Item number
4033 000 022 0
Designation
Centronic SunWindControl SWC510
Technical data
Mains frequency
50 Hz
Can be integrated into the switch frame
no
Colour
Grey
Length
190 mm
Weight
0.669 kg
Switching current max.
µ 5A / 230V / AC cos Φ = 1
Wall bracket included
Dimensions
B x H x T: 150 x 190 x 50 mm
Width
150 mm
Number of channels
1
Power supply (AC/DC)
Alternating current
Intermediate positions
2
Type of mounting
Surface mounted
Height/depth
50 mm
IP degree of protection
44
Rated voltage
230 V
Dimensional drawing
Additional features
Intermediate positions
2
Sensor functions
Sensor values - evaluable
- Sun
- Wind
Sensor values - detection
- Wind
- Sun
Assembly and operating instructions
Declarations of conformity
Miscellaneous
Problem:
Drive is not functioning.
Remedy:
Drive is running in the wrong direction.
Remedy:
Automatic drive commands are not executed.
Remedy:
System does not extend automatically when slide switch is set to SUN.
Remedy:
The sensor does not perform the manual drive commands from a hand-held transmitter.
Remedy:
Drive is not functioning.
Remedy:
- Check the electrical connection.
____________________________________________
Drive is running in the wrong direction.
Remedy:
- Swap the drive wires for OPEN and CLOSE.
____________________________________________
Automatic drive commands are not executed.
Remedy:
- Set the slide switch on the manual/wall transmitter to SUN.
- Program transmitter.
____________________________________________
System does not extend automatically when slide switch is set to SUN.
Remedy:
- Adjust sun threshold value.
- Wind threshold value exceeded. Wait for the wind to die down.
Problem:
System does not extend manually when slide switch is set to SUN or MANUAL.
Remedy:
System does not extend manually when slide switch is set to SUN or MANUAL.
Remedy:
- Wind threshold value exceeded. Wait for the wind to die down.
____________________________________________
The sensor does not perform the manual drive commands from a hand-held transmitter.
Remedy:
- Program transmitter.
____________________________________________
Accessories for this item