Usage recommendation
- Drop-arm awning
- Roller shutter
- Roller door
- Open/semi-open articulated-arm awning
- Markisolette/window awning
- Insect protection
- Guided
Certifications
Product highlights
... For the user:
Made in Germany - for maximum reliability and durability
... For installation:
Limit position adjustment: Automatic detection when fixed point end-positions at top/bottom are present
... For planning:
Mechanical limit switching
General product data
Designation
R7-17-M04
Sales unit
pc.
Series
M04
Item number
2010 110 041 0
RRP (incl. VAT)
229,00 €
GTIN
4251852900833
Drive diameter
Ø 45mm = R
Technical data
Weight
1.757 kg
Mains frequency
50 Hz
Power consump.
90 W
Rated current
0.45 A
Rated voltage
230 V
Power supply (AC/DC)
Alternating current
IP degree of protection
44
Duty cycle
S2 4 min
Colour
White (RAL 9016)
Speed (load)
14 U/min
Drive torque (Nm)
7 Nm
Speed (rpm)
17 U/min
Cable type
Rubber - S05RN-F4G0.75 - white
Cable length
3 m
Dimensions
Dimension L1
354 mm
Dimension L2
394 mm
Dimension L3
411 mm
Dimension L4
17 mm
Dimension L5
40 mm
Dimension Ø c
45 mm
Dimensional drawing
Drive adapter width from Drive adapter S60L (4930 300 466 0), when selecting a different drive adapter, the dimensions L2, L3 and L5 will change
Special features
Motor head can be overwrapped
Additional features
Drive can be operated by wired operator control
Assembly and operating instructions
Miscellaneous
Problem:
Tubular drive does not run in the right direction.
Remedy:
limit positions.
Stops have broken off or one or several attachments are broken. Repair system; delete limit positions,
re-program limit positions
Tubular drive does not run in the right direction.
Remedy:
Tubular drive does not run in the right direction.
Remedy:
- Tubular drive is overheated. The tubular drive is operational again after a few minutes.
- Tubular drive is faulty (does not run even after standing still for a long period of time). Replace the tubular drive.
- Clear and remove the obstruction and switch in the desired direction. Check the electrical connection.
____________________________________________
limit positions.
____________________________________________
Stops have broken off or one or several attachments are broken. Repair system; delete limit positions,
re-program limit positions
____________________________________________
Tubular drive does not run in the right direction.
Remedy:
- Tubular drive is overheated. The tubular drive is operational again after a few minutes.
- Tubular drive is faulty (does not run even after standing still for a long period of time). Replace the tubular drive.
- Clear and remove the obstruction and switch in the desired direction. Check the electrical connection.
____________________________________________
This may also interest you!