Usage recommendation
- Guided
- Insect protection
- Roller shutter
- Volants
Certifications
Product highlights
... For the user:
Made in Germany - for maximum reliability and durability
... For installation:
Limit position adjustment: Automatic detection when fixed point end-positions at top/bottom are present
... For planning:
Mechanical limit switching
General product data
GTIN
4251852901939
RRP (incl. VAT)
384,00 €
Series
M19
Sales unit
pc.
Designation
P10-11-M19
Item number
2006 060 012 0
Drive diameter
Ø 35mm = P
Technical data
IP degree of protection
44
Mains frequency
0 Hz
Speed (load)
7 U/min
Weight
1.157 kg
Colour
White (RAL 9016)
Power supply (AC/DC)
DC
Power consump.
23 W
Rated current
1.9 A
Rated voltage
12 V
Duty cycle
S2 4 min
Drive torque (Nm)
10 Nm
Speed (rpm)
11 U/min
Cable type
Rubber - S05RN-F 4x1 white
Cable length
3 m
Dimensions
Dimension L1
449 mm
Dimension L2
466 mm
Dimension L3
479 mm
Dimension L4
13 mm
Dimension L5
17 mm
Dimension Ø c
35 mm
Dimensional drawing
Drive adapter width from Drive adapter 40 x 1/42 x 2 (4930 300 086 0), when selecting a different drive adapter, the dimensions L2, L3 and L5 will change
Special features
Motor head can be overwrapped
Additional features
Drive can be operated by wired operator control
Assembly and operating instructions
Miscellaneous
Problem:
Tubular drive does not run in the right direction.
Remedy:
limit positions.
Stops have broken off or one or several attachments are broken. Repair system; delete limit positions,
re-program limit positions
Tubular drive does not run in the right direction.
Remedy:
Tubular drive does not run in the right direction.
Remedy:
- Tubular drive is overheated. The tubular drive is operational again after a few minutes.
- Tubular drive is faulty (does not run even after standing still for a long period of time). Replace the tubular drive.
- Clear and remove the obstruction and switch in the desired direction. Check the electrical connection.
____________________________________________
limit positions.
____________________________________________
Stops have broken off or one or several attachments are broken. Repair system; delete limit positions,
re-program limit positions
____________________________________________
Tubular drive does not run in the right direction.
Remedy:
- Tubular drive is overheated. The tubular drive is operational again after a few minutes.
- Tubular drive is faulty (does not run even after standing still for a long period of time). Replace the tubular drive.
- Clear and remove the obstruction and switch in the desired direction. Check the electrical connection.