Usage recommendation
- Guided
- Markisolette/window awning
- Drop-arm awning
- Roller shutter
- Roller door
- Insect protection
- Open/semi-open articulated-arm awning
Certifications
Product highlights
... For the user:
Made in Germany - for maximum reliability and durability
... For installation:
Limit position adjustment: Automatic detection when fixed point end-positions at top/bottom are present
... For planning:
C-Plug pluggable connecting cable
Mechanical limit switching
General product data
GTIN
4251852900987
Series
M04
Item number
2050 110 106 0
Designation
L50-17-M04
Sales unit
pc.
Drive diameter
Ø 58mm = L
RRP (incl. VAT)
344,00 €
Technical data
Rated current
1.4 A
Rated voltage
230 V
Mains frequency
50 Hz
IP degree of protection
44
Weight
4.739 kg
Colour
White (RAL 9016)
Duty cycle
S2 4 min
Speed (load)
14 U/min
Power supply (AC/DC)
Alternating current
Power consump.
315 W
Drive torque (Nm)
50 Nm
Speed (rpm)
17 U/min
Cable type
plug-in
Dimensions
Dimension L1
672 mm
Dimension L2
702 mm
Dimension L3
722 mm
Dimension L4
20 mm
Dimension L5
30 mm
Dimension Ø c
58 mm
Dimensional drawing
Drive adapter width from Drive adapter SM70 (4931 300 080 0), when selecting a different drive adapter, the dimensions L2, L3 and L5 will change
Special features
Motor head can be overwrapped
Additional features
Drive can be operated by wired operator control
Assembly and operating instructions
Miscellaneous
Problem:
Tubular drive does not run in the right direction.
Remedy:
limit positions.
Stops have broken off or one or several attachments are broken. Repair system; delete limit positions,
re-program limit positions
Tubular drive does not run in the right direction.
Remedy:
Tubular drive does not run in the right direction.
Remedy:
- Tubular drive is overheated. The tubular drive is operational again after a few minutes.
- Tubular drive is faulty (does not run even after standing still for a long period of time). Replace the tubular drive.
- Clear and remove the obstruction and switch in the desired direction. Check the electrical connection.
____________________________________________
limit positions.
____________________________________________
Stops have broken off or one or several attachments are broken. Repair system; delete limit positions,
re-program limit positions
____________________________________________
Tubular drive does not run in the right direction.
Remedy:
- Tubular drive is overheated. The tubular drive is operational again after a few minutes.
- Tubular drive is faulty (does not run even after standing still for a long period of time). Replace the tubular drive.
- Clear and remove the obstruction and switch in the desired direction. Check the electrical connection.
____________________________________________
* C-plug connecting cables are available in various versions and lengths and must be ordered separately.