Usage recommendation
- Horizontal screen
- Articulated-arm cassette awning
- Conservatory awning
- Drop-arm awning
- Pergola
- Open/semi-open articulated-arm awning
- Markisolette/window awning
- Volants
- Guided
Certifications
Product highlights
... For the user:
Fabric untensioning can be switched on/off in the upper limit position
Enables programming of 2 freely selectable intermediate positions
Optional activation: Fabric tensioning function
Made in Germany - for maximum reliability and durability
The mesh technology allows individual drives to connect together automatically to form a very efficient network
Blockage detection in both directions with automatic reversal and multiple testing
Higher closing force for cassette awnings
Wireless software update via DECT central controls, e.g. FRITZ!Box
Compatible with sun/wind/rain sensors for maximum convenience
Memory function: Integrated timer can be activated via MemoControl transmitter
... For installation:
Switch on the motor head to change the direction of rotation and to activate and deactivate programming mode
Automatic shading solution length adjustment
Intelligent installation management permits limit position corrections
Auto-install function
Limit positions status indicator (LSI) signals missing limit positions
Lower limit position adjustment: point (automatic detection or freely programmable), Upper limit position adjustment: point or stop
Switchable stop behaviour
Convenient threshold adjustment via the hand-held transmitter or central control units
... For planning:
Integrated radio receiver compatible with the Centronic control unit range
Integrated CentronicPlus radio transceiver: Bidirectional, 868.3 MHz, the drive reports back its position, any blockage and other status information
Integrated CentronicPlus radio transceiver: the drive reports back its position, any blockage and other status information
Centronic radio receiver integrated: compatible with Centronic range of control units
Supports parallel connection
C-Plug pluggable connecting cable
Local operation with a standard single button
Individual, group and central control possible (also by radio)
General product data
RRP (incl. VAT)
465,00 €
Designation
R50-11-C12 PLUS
Series
C12 PLUS
GTIN
4251852916223
Drive diameter
Ø 45mm = R
Item number
2050 130 192 0
Sales unit
pc.
Technical data
Speed (load)
8 U/min
IP degree of protection
44
Intermediate positions
2
Power supply (AC/DC)
Alternating current
Weight
2.946 kg
Colour
White (RAL 9016)
Power consump.
240 W
Mains frequency
50 Hz
Rated voltage
230 V
Rated current
1.05 A
Duty cycle
S2 4 min
Drive torque (Nm)
50 Nm
Speed (rpm)
11 U/min
Cable type
plug-in
Dimensions
Dimension L1
540.3 mm
Dimension L2
557.3 mm
Dimension L3
574.3 mm
Dimension L4
17 mm
Dimension L5
17 mm
Dimension Ø c
45 mm
Dimensional drawing
Drive adapter width from Drive adapter DW78 R+F diecast (4930 300 091 0), when selecting a different drive adapter, the dimensions L2, L3 and L5 will change
Special features
Suitable for connection in parallel
Motor head can be overwrapped
Communication
Bidirectional product
Active participant for routing/meshing
Radio compatibility
- Centronic PLUS
- Centronic
Obstacle detection
Blockage detection in both directions
Commissioning
Higher closing force can be set
Limit position programming
Intelligent installation management (3x approach)
LSI - limit positions status indicator
Additional features
Intermediate positions
2
Soft stop upper limit position
7-Stage - stage 5
Time function
Memory
Drive can be operated by wired operator control
Fabric untensioning - reversal at the retracted stop- factory default
Fabric untensioning - reversal at the retracted stop
5° - can be activated/deactivated at any time
Sensor functions
Sensor values - evaluable
- Rain
- Twilight
- Wind
- Frost
- Temperature
- Sun
Time function
Time function
Memory
Assembly and operating instructions
Declarations of conformity
Miscellaneous
selected item
Tubular drive does not run in the right direction.
Remedy:
Problem:
Drive is not functioning.
Remedy:
Problem:
Incorrect running direction after deleting limit positions.
Remedy:
Problem:
The LED ring lights up red when the receiver for the setting mode is selected.
Remedy:
Problem:
During the programming run, the drive stops short of the limit position to be programmed.
Remedy:
____________________________________________
Tubular drive does not run in the right direction.
Remedy:
- Tubular drive is overheated. The tubular drive is operational again after a few minutes.
- Tubular drive is faulty (does not run even after standing still for a long period of time). Replace the tubular drive.
- Clear and remove the obstruction and switch in the desired direction. Check the electrical connection.
____________________________________________
Problem:
Drive is not functioning.
Remedy:
- Program new transmitter.
- Bring transmitter within range of the tubular drive.
- Press drive or stop button on transmitter at least five times in the immediate vicinity of the tubular drive.
- Insert battery/batteries correctly in the transmitter or insert new battery/batteries.
- Check electrical connection.
- Thermal protection switch in tubular drive has tripped. Wait until the thermal protection switch in the tubular drive is reactivated.
Problem:
Running direction on tubular drive cannot be set
Remedy:
Running direction on tubular drive cannot be set
Remedy:
- Delete limit positions and reset the running direction.
____________________________________________
Problem:
Incorrect running direction after deleting limit positions.
Remedy:
- Use the relevant transmitter or the direction switch on the tubular drive to change the direction of rotation.
____________________________________________
Problem:
The LED ring lights up red when the receiver for the setting mode is selected.
Remedy:
- Reduce the distance from the receiver.
- Check the electrical connection of the receiver.
- Put the receiver into programming mode.
- Add the transmitter to the installation.
Problem:
The required setting cannot be changed.
Remedy:
The required setting cannot be changed.
Remedy:
- Make sure that the CentronicPlus transmitter is in programming mode.
____________________________________________
Problem:
During the programming run, the drive stops short of the limit position to be programmed.
Remedy:
- For safety reasons, the drive reacts sensitively to sluggishness during the programming run, in order to prevent damage. Briefly run roller shutter DOWN and then UP until you reach the upper limit position.
____________________________________________
* C-plug connecting cables are available in various versions and lengths and must be ordered separately.