Usage recommendation
Zip screen
Certifications
Product highlights
... For the user:
Enables programming of 2 freely selectable intermediate positions
Wireless software update via DECT central controls, e.g. FRITZ!Box
Made in Germany - for maximum reliability and durability
Memory function: Integrated timer can be activated via MemoControl transmitter
Sensitive obstacle detection with multiple testing
Compatible with sun/wind/rain sensors for maximum convenience
The mesh technology allows individual drives to connect together automatically to form a very efficient network
Fabric untensioning can be switched on/off in the upper limit position
Blockage detection in both directions with automatic reversal and multiple testing
... For installation:
Lower limit position adjustment: point (automatic detection or freely programmable), Upper limit position adjustment: point or stop
Switch on the motor head to change the direction of rotation and to activate and deactivate programming mode
Convenient threshold adjustment via the hand-held transmitter or central control units
Automatic shading solution length adjustment
Limit positions status indicator (LSI) signals missing limit positions
Auto-install function
Intelligent installation management permits limit position corrections
... For planning:
Integrated radio receiver compatible with the Centronic control unit range
Integrated CentronicPlus radio transceiver: Bidirectional, 868.3 MHz, the drive reports back its position, any blockage and other status information
C-Plug pluggable connecting cable
Local operation with a standard single button
Individual, group and central control possible (also by radio)
Supports parallel connection
General product data
Series
C18 PLUS
Sales unit
pc.
RRP (incl. VAT)
476,00 €
GTIN
4251852916414
Drive diameter
Ø 45mm = R
Designation
R30-17-C18 PLUS
Item number
2030 130 189 0
Technical data
Power consump.
210 W
Colour
White (RAL 9016)
IP degree of protection
44
Duty cycle
S2 4 min
Rated current
0.9 A
Speed (load)
14 U/min
Intermediate positions
2
Weight
2.762 kg
Power supply (AC/DC)
Alternating current
Mains frequency
50 Hz
Rated voltage
230 V
Drive torque (Nm)
30 Nm
Speed (rpm)
17 U/min
Cable type
plug-in
Dimensions
Dimension L1
530 mm
Dimension L2
570 mm
Dimension L3
587 mm
Dimension L4
17 mm
Dimension L5
40 mm
Dimension Ø c
45 mm
Drive adapter width from Drive adapter DW78 for obstruction detection (4930 200 274 0), when selecting a different drive adapter, the dimensions L2, L3 and L5 will change
Special features
Suitable for connection in parallel
Motor head can be overwrapped
Communication
Bidirectional product
Active participant for routing/meshing
Radio compatibility
- Centronic PLUS
- Centronic
Obstacle detection
Obstruction detection, sensitive, in the extend direction (drive adapter)
Yes (sun protection)
Blockage detection in both directions
Commissioning
Reduced drive torque during installation
Limit position programming
Intelligent installation management (3x approach)
LSI - limit positions status indicator
Additional features
Intermediate positions
2
Soft stop upper limit position
7-Stage - stage 5
Time function
Memory
Drive can be operated by wired operator control
Fabric untensioning - reversal at the retracted stop- factory default
Fabric untensioning - reversal at the retracted stop
5° - can be activated/deactivated at any time
Sensor functions
Sensor values - evaluable
- Twilight
- Temperature
- Wind
- Rain
- Frost
- Sun
Time function
Time function
Memory
Assembly and operating instructions
Declarations of conformity
Miscellaneous
selected item
Tubular drive does not run in the right direction.
Remedy:
Problem:
Drive is not functioning.
Remedy:
Problem:
Incorrect running direction after deleting limit positions.
Remedy:
Problem:
The LED ring lights up red when the receiver for the setting mode is selected.
Remedy:
Tubular drive overruns the limit position or stops short of the set limit position.
Remedy:
Problem:
During the programming run, the drive stops short of the limit position to be programmed.
Remedy:
____________________________________________
Tubular drive does not run in the right direction.
Remedy:
- Tubular drive is overheated. The tubular drive is operational again after a few minutes.
- Tubular drive is faulty (does not run even after standing still for a long period of time). Replace the tubular drive.
- Clear and remove the obstruction and switch in the desired direction. Check the electrical connection.
____________________________________________
Problem:
Drive is not functioning.
Remedy:
- Program new transmitter.
- Bring transmitter within range of the tubular drive.
- Press drive or stop button on transmitter at least five times in the immediate vicinity of the tubular drive.
- Insert battery/batteries correctly in the transmitter or insert new battery/batteries.
- Check electrical connection.
- Thermal protection switch in tubular drive has tripped. Wait until the thermal protection switch in the tubular drive is reactivated.
Problem:
Running direction on tubular drive cannot be set
Remedy:
Running direction on tubular drive cannot be set
Remedy:
- Delete limit positions and reset the running direction.
____________________________________________
Problem:
Incorrect running direction after deleting limit positions.
Remedy:
- Use the relevant transmitter or the direction switch on the tubular drive to change the direction of rotation.
____________________________________________
Problem:
The LED ring lights up red when the receiver for the setting mode is selected.
Remedy:
- Reduce the distance from the receiver.
- Check the electrical connection of the receiver.
- Put the receiver into programming mode.
- Add the transmitter to the installation.
Problem:
The required setting cannot be changed.
Remedy:
The required setting cannot be changed.
Remedy:
- Make sure that the CentronicPlus transmitter is in programming mode.
____________________________________________
Tubular drive overruns the limit position or stops short of the set limit position.
Remedy:
- Check electrical installation, remove external devices, delete limit positions and then reset limit positions.
- Repair electrical installation and re-program limit positions.
- Stops have broken off or one or several attachments are broken. Repair system; reset tubular drive, then re-program limit positions.
____________________________________________
Problem:
During the programming run, the drive stops short of the limit position to be programmed.
Remedy:
- For safety reasons, the drive reacts sensitively to sluggishness during the programming run, in order to prevent damage. Briefly run roller shutter DOWN and then UP until you reach the upper limit position.
____________________________________________
* C-plug connecting cables are available in various versions and lengths and must be ordered separately.