Usage recommendation
Zip screen
Certifications
As a follow-up/alternative item for this product we recommend:
Product highlights
... For the user:
Sensitive obstacle detection with multiple testing
Made in Germany - for maximum reliability and durability
Memory function: Integrated timer can be activated via MemoControl transmitter
Enables programming of 2 freely selectable intermediate positions
Compatible with sun/wind/rain sensors for maximum convenience
Blockage detection in both directions with automatic reversal and multiple testing
Fabric untensioning can be switched on/off in the upper limit position
... For installation:
Auto-install function
Limit positions status indicator (LSI) signals missing limit positions
Switch on the motor head to change the direction of rotation and to activate and deactivate programming mode
Convenient threshold adjustment via the hand-held transmitter or central control units
Lower limit position adjustment: point (automatic detection or freely programmable), Upper limit position adjustment: point or stop
Automatic shading solution length adjustment
Intelligent installation management permits limit position corrections
... For planning:
Local operation with a standard single button
Integrated radio receiver compatible with the Centronic control unit range
Supports parallel connection
C-Plug pluggable connecting cable
Individual, group and central control possible (also by radio)
General product data
Series
C18
Sales unit
pc.
RRP (incl. VAT)
430,00 €
GTIN
4251852906309
Drive diameter
Ø 45mm = R
Designation
R12-17-C18
Item number
2010 130 164 0
Technical data
Power consump.
110 W
Colour
White (RAL 9016)
IP degree of protection
44
Duty cycle
S2 4 min
Rated current
0.5 A
Speed (load)
14 U/min
Intermediate positions
2
Weight
1.9 kg
Power supply (AC/DC)
Alternating current
Mains frequency
50 Hz
Rated voltage
230 V
Drive torque (Nm)
12 Nm
Speed (rpm)
17 U/min
Cable type
plug-in
Dimensions
Dimension L1
472.6 mm
Dimension L2
512.6 mm
Dimension L3
529.6 mm
Dimension L4
17 mm
Dimension L5
40 mm
Dimension Ø c
45 mm
Dimensional drawing
Drive adapter width from Drive adapter DW78 for obstruction detection (4930 200 274 0), when selecting a different drive adapter, the dimensions L2, L3 and L5 will change
Special features
Suitable for connection in parallel
Motor head can be overwrapped
Communication
Radio compatibility
Centronic
Obstacle detection
Obstruction detection, sensitive, in the extend direction (drive adapter)
Yes (sun protection)
Blockage detection in both directions
Commissioning
Reduced drive torque during installation
Limit position programming
Intelligent installation management (3x approach)
LSI - limit positions status indicator
Additional features
Intermediate positions
2
Soft stop upper limit position
7-Stage - stage 5
Time function
Memory
Drive can be operated by wired operator control
Fabric untensioning - reversal at the retracted stop- factory default
Fabric untensioning - reversal at the retracted stop
5° - can be activated/deactivated at any time
Sensor functions
Sensor values - evaluable
- Sun
- Rain
- Wind
Time function
Time function
Memory
Assembly and operating instructions
Declarations of conformity
selected item
Tubular drive does not run in the right direction.
Remedy:
Problem:
Drive is not functioning.
Remedy:
Problem:
Incorrect running direction after deleting limit positions.
Remedy:
Tubular drive overruns the limit position or stops short of the set limit position.
Remedy:
Problem:
Tubular drive switches off automatically before the first limit position is programmed.
Remedy:
Problem:
Setting the limit positions using Auto-install does not work.
Remedy:
Problem:
Tubular drive only runs for approx. 1 second.
Remedy:
Problem:
Tubular drive encounters an obstruction and reverses. However, it does not double-check again whether the obstruction is still there.
Remedy:
____________________________________________
Tubular drive does not run in the right direction.
Remedy:
- Tubular drive is overheated. The tubular drive is operational again after a few minutes.
- Tubular drive is faulty (does not run even after standing still for a long period of time). Replace the tubular drive.
- Clear and remove the obstruction and switch in the desired direction. Check the electrical connection.
____________________________________________
Problem:
Drive is not functioning.
Remedy:
- Program new transmitter.
- Bring transmitter within range of the tubular drive.
- Press drive or stop button on transmitter at least five times in the immediate vicinity of the tubular drive.
- Insert battery/batteries correctly in the transmitter or insert new battery/batteries.
- Check electrical connection.
- Thermal protection switch in tubular drive has tripped. Wait until the thermal protection switch in the tubular drive is reactivated.
Problem:
Running direction on tubular drive cannot be set
Remedy:
Running direction on tubular drive cannot be set
Remedy:
- Delete limit positions and reset the running direction.
____________________________________________
Problem:
Incorrect running direction after deleting limit positions.
Remedy:
- Use the master transmitter or the direction switch on the tubular drive to change the direction of rotation.
____________________________________________
Tubular drive overruns the limit position or stops short of the set limit position.
Remedy:
- Check electrical installation, remove external devices, delete limit positions and then reset limit positions.
- Repair electrical installation and re-program limit positions.
- Stops have broken off or one or several attachments are broken. Repair system; reset tubular drive, then re-program limit positions.
____________________________________________
Problem:
Tubular drive switches off automatically before the first limit position is programmed.
Remedy:
- Tubular drive has detected a torque increase.
- Clear and remove the obstruction. Then move past this position to the desired limit position.
____________________________________________
Problem:
Setting the limit positions using Auto-install does not work.
Remedy:
- Move to the desired extended limit position and set a point.
- Use a heavier end strip.
____________________________________________
Problem:
Tubular drive only runs for approx. 1 second.
Remedy:
- Tubular drive is faulty. Replace the tubular drive.
____________________________________________
Problem:
Tubular drive encounters an obstruction and reverses. However, it does not double-check again whether the obstruction is still there.
Remedy:
- The installation is not yet complete. Travel to the limit position Stop three times.
____________________________________________
* C-plug connecting cables are available in various versions and lengths and must be ordered separately.