Usage recommendation
- Volants
- Open/semi-open articulated-arm awning
- Horizontal screen
- Conservatory awning
- Guided
- Articulated-arm cassette awning
- Drop-arm awning
- Pergola
- Markisolette/window awning
Certifications
Product highlights
... For the user:
Fabric untensioning can be switched on/off in the upper limit position
Higher closing force for cassette awnings
Enables programming of 2 freely selectable intermediate positions
Blockage detection in both directions with automatic reversal and multiple testing
Optional activation: Fabric tensioning function
Compatible with sun/wind/rain sensors for maximum convenience
Made in Germany - for maximum reliability and durability
... For installation:
Intelligent installation management permits limit position corrections
Switch on the motor head to change the direction of rotation and to activate and deactivate programming mode
Auto-install function
Convenient threshold adjustment via the hand-held transmitter or central control units
Switchable stop behaviour
Lower limit position adjustment: point (automatic detection or freely programmable), Upper limit position adjustment: point or stop
Limit positions status indicator (LSI) signals missing limit positions
Automatic shading solution length adjustment
... For planning:
Individual, group and central control possible (also by radio)
Integrated radio receiver compatible with the Centronic control unit range
Supports parallel connection
Local operation with a standard single button
C-Plug pluggable connecting cable
General product data
Series
C12
Sales unit
pc.
RRP (incl. VAT)
522,00 €
GTIN
4251852905401
Drive diameter
Ø 58mm = L
Designation
L60-11-C12
Item number
2060 130 144 0
Technical data
Power consump.
265 W
Colour
White (RAL 9016)
IP degree of protection
44
Duty cycle
S2 4 min
Rated current
1.2 A
Speed (load)
8 U/min
Intermediate positions
2
Weight
4.057 kg
Power supply (AC/DC)
Alternating current
Mains frequency
50 Hz
Rated voltage
230 V
Drive torque (Nm)
60 Nm
Speed (rpm)
11 U/min
Cable type
plug-in
Dimensions
Dimension L1
532.5 mm
Dimension L2
562.5 mm
Dimension L3
583.8 mm
Dimension L4
20 mm
Dimension L5
30 mm
Dimension Ø c
58 mm
Dimensional drawing
Drive adapter width from Drive adapter DW78N 1.5 mm centre offset (4931 300 365 0), when selecting a different drive adapter, the dimensions L2, L3 and L5 will change
Special features
Suitable for connection in parallel
Motor head can be overwrapped
Communication
Radio compatibility
Centronic
Obstacle detection
Blockage detection in both directions
Commissioning
Higher closing force can be set
Limit position programming
Intelligent installation management (3x approach)
LSI - limit positions status indicator
Additional features
Intermediate positions
2
Soft stop upper limit position
7-Stage - stage 5
Drive can be operated by wired operator control
Fabric untensioning - reversal at the retracted stop- factory default
Fabric untensioning - reversal at the retracted stop
5° - can be activated/deactivated at any time
Sensor functions
Sensor values - evaluable
- Wind
- Rain
- Sun
Assembly and operating instructions
Miscellaneous
selected item
Tubular drive does not run in the right direction.
Remedy:
Problem:
Drive is not functioning.
Remedy:
Problem:
Incorrect running direction after deleting limit positions.
Remedy:
____________________________________________
Tubular drive does not run in the right direction.
Remedy:
- Tubular drive is overheated. The tubular drive is operational again after a few minutes.
- Tubular drive is faulty (does not run even after standing still for a long period of time). Replace the tubular drive.
- Clear and remove the obstruction and switch in the desired direction. Check the electrical connection.
____________________________________________
Problem:
Drive is not functioning.
Remedy:
- Program new transmitter.
- Bring transmitter within range of the tubular drive.
- Press drive or stop button on transmitter at least five times in the immediate vicinity of the tubular drive.
- Insert battery/batteries correctly in the transmitter or insert new battery/batteries.
- Check electrical connection.
- Thermal protection switch in tubular drive has tripped. Wait until the thermal protection switch in the tubular drive is reactivated.
Problem:
Running direction on tubular drive cannot be set
Remedy:
Running direction on tubular drive cannot be set
Remedy:
- Delete limit positions and reset the running direction.
____________________________________________
Problem:
Incorrect running direction after deleting limit positions.
Remedy:
- Use the master transmitter or the direction switch on the tubular drive to change the direction of rotation.
____________________________________________
* C-plug connecting cables are available in various versions and lengths and must be ordered separately.