Usage recommendation
- Pergola
- Open/semi-open articulated-arm awning
- Volants
- Markisolette/window awning
- Articulated-arm cassette awning
- Guided
- Conservatory awning
- Insect protection
- Drop-arm awning
- Horizontal screen
Certifications
Product highlights
... For the user:
Optional activation: Fabric tensioning function
Fabric untensioning can be switched on/off in the upper limit position
Made in Germany - for maximum reliability and durability
Higher closing force for cassette awnings
Blockage detection in both directions with automatic reversal and multiple testing
... For installation:
Limit positions status indicator (LSI) signals missing limit positions
Lower limit position adjustment: point (automatic detection or freely programmable), Upper limit position adjustment: point or stop
Auto-install function
Setting of limit positions via switch on the drive head without the need for a special programming unit
Intelligent installation management permits limit position corrections
Switchable stop behaviour
Automatic shading solution length adjustment
... For planning:
Electronic limit switching
Supports parallel connection
C-Plug pluggable connecting cable
General product data
RRP (incl. VAT)
275,00 €
GTIN
4251852903049
Drive diameter
Ø 45mm = R
Designation
R8-17-E12
Series
E12
Item number
2010 130 161 0
Sales unit
pc.
Technical data
Rated voltage
230 V
Rated current
0.45 A
Weight
1.9 kg
IP degree of protection
44
Mains frequency
50 Hz
Power supply (AC/DC)
Alternating current
Duty cycle
S2 4 min
Speed (load)
14 U/min
Colour
White (RAL 9016)
Power consump.
100 W
Drive torque (Nm)
8 Nm
Speed (rpm)
17 U/min
Cable type
plug-in
Dimensions
Dimension L1
472.6 mm
Dimension L2
489.6 mm
Dimension L3
506.6 mm
Dimension L4
17 mm
Dimension L5
17 mm
Dimension Ø c
45 mm
Dimensional drawing
Drive adapter width from Drive adapter DW78 R+F diecast (4930 300 091 0), when selecting a different drive adapter, the dimensions L2, L3 and L5 will change
Special features
Suitable for connection in parallel
Motor head can be overwrapped
Obstacle detection
Blockage detection in both directions
Commissioning
Higher closing force can be set
Limit position programming
Intelligent installation management (3x approach)
LSI - limit positions status indicator
Additional features
Soft stop upper limit position
7-Stage - stage 5
Drive can be operated by wired operator control
Fabric untensioning - reversal at the retracted stop- factory default
Fabric untensioning - reversal at the retracted stop
5° - can be activated/deactivated at any time
Assembly and operating instructions
Declarations of conformity
Miscellaneous
Problem:
Tubular drive overruns the limit position or stops short of the set limit position.
Remedy:
Tubular drive does not run in the right direction.
Remedy:
Problem:
Setting the limit positions using the programming unit does not work.
Remedy:
Problem:
Tubular drive switches off automatically before the first limit position is programmed.
Remedy:
Problem:
Setting the limit positions using Auto-install does not work.
Remedy:
Problem:
The stop behaviour cannot be changed.
Remedy:
Problem:
Tubular drive only runs for approx. 1 second.
Remedy:
Tubular drive overruns the limit position or stops short of the set limit position.
Remedy:
- Check electrical installation, remove external devices, delete limit positions and then reset limit positions.
- Repair electrical installation and re-program limit positions.
- Stops have broken off or one or several attachments are broken. Repair system; reset tubular drive, then re-program limit positions.
____________________________________________
____________________________________________
Tubular drive does not run in the right direction.
Remedy:
- Tubular drive is overheated. The tubular drive is operational again after a few minutes.
- Tubular drive is faulty (does not run even after standing still for a long period of time). Replace the tubular drive.
- Clear and remove the obstruction and switch in the desired direction. Check the electrical connection.
____________________________________________
Problem:
Setting the limit positions using the programming unit does not work.
Remedy:
- Set both switches to the delete setting.
- Execute a short drive command.
- Set both switches to the programming setting simultaneously.
- Re-set the limit positions using the programming unit.
Problem:
Setting the limit positions using the switch on the drive head does not work.
Remedy:
Setting the limit positions using the switch on the drive head does not work.
Remedy:
- Set both switches to the delete setting.
- Execute a short drive command.
- Re-set the limit positions.
____________________________________________
Problem:
Tubular drive switches off automatically before the first limit position is programmed.
Remedy:
- Tubular drive has detected a torque increase.
- Clear and remove the obstruction. Then move past this position to the desired limit position.
____________________________________________
Problem:
Setting the limit positions using Auto-install does not work.
Remedy:
- Move to the desired extended limit position and set a point.
____________________________________________
Problem:
The stop behaviour cannot be changed.
Remedy:
- Move to the stop limit position, and delete it individually using the programming unit. Move the system to a point between the limit positions. You can now change the stop behaviour.
____________________________________________
Problem:
Tubular drive only runs for approx. 1 second.
Remedy:
- Tubular drive is faulty. Replace the tubular drive.
____________________________________________
* C-plug connecting cables are available in various versions and lengths and must be ordered separately.