Usage recommendation
Sun protection systems with locking mechanism
Certifications
Product highlights
... For the user:
Made in Germany - for maximum reliability and durability
Optional activation: Fabric tensioning function
Fabric untensioning can be switched on/off in the upper limit position
Blockage detection in the UP direction (anti-freeze mechanism)
... For installation:
Automatic shading solution length adjustment
Limit positions status indicator (LSI) signals missing limit positions
Setting limit positions: Automatic detection with existing upper stop and fixed point lower limit position programming
Intelligent installation management permits limit position corrections
... For planning:
Electronic limit switching
C-Plug pluggable connecting cable
Supports parallel connection
For locking systems: The drive locks and unlocks automatically in the lower limit position
General product data
Designation
L70-17-E16
Item number
2070 130 138 0
RRP (incl. VAT)
510,00 €
Series
E16
GTIN
4251852904596
Drive diameter
Ø 58mm = L
Sales unit
pc.
Technical data
Weight
4.9 kg
Power supply (AC/DC)
Alternating current
Mains frequency
50 Hz
Power consump.
430 W
Rated current
1.9 A
Speed (load)
14 U/min
IP degree of protection
44
Colour
White (RAL 9016)
Duty cycle
S2 4 min
Rated voltage
230 V
Drive torque (Nm)
70 Nm
Speed (rpm)
17 U/min
Cable type
plug-in
Dimensions
Dimension L1
588.85 mm
Dimension L2
618.85 mm
Dimension L3
638.85 mm
Dimension L4
20 mm
Dimension L5
30 mm
Dimension Ø c
58 mm
Dimensional drawing
Drive adapter width from Drive adapter DW78N 1.5 mm centre offset (4931 300 365 0), when selecting a different drive adapter, the dimensions L2, L3 and L5 will change
Special features
Suitable for connection in parallel
Motor head can be overwrapped
Obstacle detection
Blockage detection in both directions
Limit position programming
Intelligent installation management (3x approach)
LSI - limit positions status indicator
Additional features
Soft stop upper limit position
7-Stage - stage 5
Drive can be operated by wired operator control
Fabric untensioning - reversal at the retracted stop
5° - can be activated/deactivated at any time
Assembly and operating instructions
Miscellaneous
Problem:
Tubular drive overruns the limit position or stops short of the set limit position.
Remedy:
Tubular drive does not run in the right direction.
Remedy:
Problem:
Tubular drive only runs for approx. 1 second.
Remedy:
Tubular drive overruns the limit position or stops short of the set limit position.
Remedy:
- Check electrical installation, remove external devices, delete limit positions and then reset limit positions.
- Repair electrical installation and re-program limit positions.
- Stops have broken off or one or several attachments are broken. Repair system; reset tubular drive, then re-program limit positions.
____________________________________________
____________________________________________
Tubular drive does not run in the right direction.
Remedy:
- Tubular drive is overheated. The tubular drive is operational again after a few minutes.
- Tubular drive is faulty (does not run even after standing still for a long period of time). Replace the tubular drive.
- Clear and remove the obstruction and switch in the desired direction. Check the electrical connection.
____________________________________________
Problem:
Tubular drive only runs for approx. 1 second.
Remedy:
- Tubular drive is faulty. Replace the tubular drive.
____________________________________________
* C-plug connecting cables are available in various versions and lengths and must be ordered separately.