Problem: Tubular drive does not run in the right direction.
Remedy:- Tubular drive is overheated. The tubular drive is operational again after a few minutes.
- Tubular drive is faulty (does not run even after standing still for a long period of time). Replace the tubular drive.
- Clear and remove the obstruction and switch in the desired direction. Check the electrical connection.
____________________________________________
selected item
____________________________________________
Problem: Tubular drive does not run in the right direction.
Remedy:- Tubular drive is overheated. The tubular drive is operational again after a few minutes.
- Tubular drive is faulty (does not run even after standing still for a long period of time). Replace the tubular drive.
- Clear and remove the obstruction and switch in the desired direction. Check the electrical connection.
____________________________________________
Problem:Tubular drive overruns the limit position or stops short of the set limit position.
Remedy:
- Check electrical installation, remove external devices, delete limit positions and then reset limit positions.
- Repair electrical installation and re-program limit positions.
- Stops have broken off or one or several attachments are broken. Repair system; reset tubular drive, then re-program limit positions.
____________________________________________
Problem: The tubular drive does not function correctly in SMI mode.
Remedy:- Check the electrical connection.
Problem: In BUS mode, the tubular drive extends the sun protection device with retraction commands or retracts it with extension commands.
Remedy:- Disconnect the tubular drive from the SMI BUS. Delete the limit positions, switch the direction switch to the opposite position and test the direction of travel with the programming unit. Re-program the limit positions.
____________________________________________
Problem: Tubular drive switches off automatically before the first limit position is programmed.
Remedy: - Tubular drive has detected a torque increase.
- Clear and remove the obstruction. Then move past this position to the desired limit position.
____________________________________________
Problem: Setting the limit positions using Auto-install does not work.
Remedy: - Move to the desired extended limit position and set a point.
____________________________________________
Problem: Tubular drive only runs for approx. 1 second.
Remedy: - Tubular drive is faulty. Replace the tubular drive.
____________________________________________