Usage recommendation
Zip screen
Certifications
Product highlights
... For the user:
Blockage detection in both directions with automatic reversal and multiple testing
Made in Germany - for maximum reliability and durability
Fabric untensioning can be switched on/off in the upper limit position
Sensitive obstacle detection with multiple testing
... For installation:
Adjustable direction of rotation
Lower limit position adjustment: point (automatic detection or freely programmable), Upper limit position adjustment: point or stop
Automatic shading solution length adjustment
Auto-install function
Intelligent installation management permits limit position corrections
Limit positions status indicator (LSI) signals missing limit positions
... For planning:
Supports parallel connection
C-Plug pluggable connecting cable
Integrated SMI technology
General product data
RRP (incl. VAT)
419,00 €
Designation
P5-16-S18
Series
S18
GTIN
4251852907344
Drive diameter
Ø 35mm = P
Item number
2009 130 512 0
Sales unit
pc.
Technical data
Speed (load)
13 U/min
IP degree of protection
44
Power supply (AC/DC)
Alternating current
Weight
1.4391 kg
Colour
White (RAL 9016)
Power consump.
80 W
Mains frequency
50 Hz
Rated voltage
230 V
Rated current
0.35 A
Duty cycle
S2 4 min
Drive torque (Nm)
5 Nm
Speed (rpm)
16 U/min
Cable type
plug-in
Dimensions
Dimension L1
423 mm
Dimension L2
463 mm
Dimension L3
476 mm
Dimension L4
13 mm
Dimension L5
40 mm
Dimension Ø c
35 mm
Dimensional drawing
Drive adapter width from Drive adapter 40x1.3 / 40x1.5 for obstruction detection (4930 200 246 0), when selecting a different drive adapter, the dimensions L2, L3 and L5 will change
Special features
Suitable for connection in parallel
Motor head can be overwrapped
Communication
Bidirectional product
Obstacle detection
Obstruction detection, sensitive, in the extend direction (drive adapter)
Yes (sun protection)
Blockage detection in both directions
Commissioning
Reduced drive torque during installation
Limit position programming
Intelligent installation management (3x approach)
LSI - limit positions status indicator
Fly screen and freeze protection function
Fly screen protection function
140° - cannot be deactivated
Additional features
Soft stop upper limit position
7-Stage - stage 5
Fabric untensioning - reversal at the retracted stop- factory default
Fabric untensioning - reversal at the retracted stop
5° - can be activated/deactivated at any time
Assembly and operating instructions
Miscellaneous
Problem:
Tubular drive does not run in the right direction.
Remedy:
Tubular drive does not run in the right direction.
Remedy:
Tubular drive overruns the limit position or stops short of the set limit position.
Remedy:
Problem:
The tubular drive does not function correctly in SMI mode.
Remedy:
Problem:
Tubular drive switches off automatically before the first limit position is programmed.
Remedy:
Problem:
Setting the limit positions using Auto-install does not work.
Remedy:
Problem:
Tubular drive only runs for approx. 1 second.
Remedy:
Tubular drive does not run in the right direction.
Remedy:
- Tubular drive is overheated. The tubular drive is operational again after a few minutes.
- Tubular drive is faulty (does not run even after standing still for a long period of time). Replace the tubular drive.
- Clear and remove the obstruction and switch in the desired direction. Check the electrical connection.
____________________________________________
____________________________________________
Tubular drive does not run in the right direction.
Remedy:
- Tubular drive is overheated. The tubular drive is operational again after a few minutes.
- Tubular drive is faulty (does not run even after standing still for a long period of time). Replace the tubular drive.
- Clear and remove the obstruction and switch in the desired direction. Check the electrical connection.
____________________________________________
Tubular drive overruns the limit position or stops short of the set limit position.
Remedy:
- Check electrical installation, remove external devices, delete limit positions and then reset limit positions.
- Repair electrical installation and re-program limit positions.
- Stops have broken off or one or several attachments are broken. Repair system; reset tubular drive, then re-program limit positions.
____________________________________________
Problem:
The tubular drive does not function correctly in SMI mode.
Remedy:
- Check the electrical connection.
Problem:
In BUS mode, the tubular drive extends the sun protection device with retraction commands or retracts it with extension commands.
Remedy:
In BUS mode, the tubular drive extends the sun protection device with retraction commands or retracts it with extension commands.
Remedy:
- Disconnect the tubular drive from the SMI BUS. Delete the limit positions, switch the direction switch to the opposite position and test the direction of travel with the programming unit. Re-program the limit positions.
____________________________________________
Problem:
Tubular drive switches off automatically before the first limit position is programmed.
Remedy:
- Tubular drive has detected a torque increase.
- Clear and remove the obstruction. Then move past this position to the desired limit position.
____________________________________________
Problem:
Setting the limit positions using Auto-install does not work.
Remedy:
- Move to the desired extended limit position and set a point.
____________________________________________
Problem:
Tubular drive only runs for approx. 1 second.
Remedy:
- Tubular drive is faulty. Replace the tubular drive.
____________________________________________
* C-plug connecting cables are available in various versions and lengths and must be ordered separately.
Accessories for this item