Usage recommendation
- Roller shutter
- Insect protection
- Roller shutters for roof windows
- Volants
- Guided
Certifications
Product highlights
... For the user:
Soft upper stop – optimum adaptation of closing forces for fabric protection
Blockage detection in the UP direction (anti-freeze mechanism)
Compatible with sun/wind/rain sensors for maximum convenience
Made in Germany - for maximum reliability and durability
Enables programming of 2 freely selectable intermediate positions
... For installation:
Automatic shading solution length adjustment
Convenient threshold adjustment via the hand-held transmitter or central control units
Intelligent installation management permits limit position corrections
Limit position adjustment: Automatic detection when stop or fixed point end-positions are present
Limit positions status indicator (LSI) signals missing limit positions
Umschaltung zwischen Rollladen- und Screenbetrieb über Steuerung möglich
... For planning:
Centronic radio receiver integrated: compatible with Centronic range of control units
Individual, group and central control possible (also by radio)
Integrated radio receiver compatible with the Centronic control unit range
General product data
Designation
P6-20-C28
Sales unit
pc.
Series
C28
Item number
2006 060 015 0
RRP (incl. VAT)
355,00 €
GTIN
4251852905142
Drive diameter
Ø 35mm = P
Technical data
Weight
0.85 kg
Mains frequency
0 Hz
Power consump.
30 W
Rated current
2.5 A
Intermediate positions
2
Rated voltage
12 V
Power supply (AC/DC)
DC
IP degree of protection
44
Duty cycle
S2 4 min
Colour
White (RAL 9016)
Speed (load)
15 U/min
Drive torque (Nm)
6 Nm
Speed (rpm)
20 U/min
Cable type
Rubber - S05RN-F 4x1 white
Cable length
0.15 m
Dimensions
Dimension L1
402 mm
Dimension L2
419 mm
Dimension L3
432 mm
Dimension L4
13 mm
Dimension L5
17 mm
Dimension Ø c
35 mm
Dimensional drawing
Drive adapter width from Drive adapter 40 x 1/42 x 2 (4930 300 086 0), when selecting a different drive adapter, the dimensions L2, L3 and L5 will change
Special features
Motor head can be overwrapped
Integrated charging electronics
Communication
Radio compatibility
Centronic
Obstacle detection
Blockage detection in both directions
Limit position programming
Intelligent installation management (3x approach)
LSI - limit positions status indicator
Additional features
Intermediate positions
2
Soft stop upper limit position
dynamic
Sensor functions
Sensor values - evaluable
- Sun
- Wind
- Rain
Assembly and operating instructions
Declarations of conformity
selected item
Tubular drive does not run in the right direction.
Remedy:
Problem:
Drive is not functioning.
Remedy:
Problem:
Tubular drive no longer moves to the lower limit position independently.
Remedy:
____________________________________________
Tubular drive does not run in the right direction.
Remedy:
- Tubular drive is overheated. The tubular drive is operational again after a few minutes.
- Tubular drive is faulty (does not run even after standing still for a long period of time). Replace the tubular drive.
- Clear and remove the obstruction and switch in the desired direction. Check the electrical connection.
____________________________________________
Problem:
Drive is not functioning.
Remedy:
- Program new transmitter.
- Bring transmitter within range of the tubular drive.
- Press drive or stop button on transmitter at least five times in the immediate vicinity of the tubular drive.
- Insert battery/batteries correctly in the transmitter or insert new battery/batteries.
- Check electrical connection.
- Thermal protection switch in tubular drive has tripped. Wait until the thermal protection switch in the tubular drive is reactivated.
Problem:
Running direction on tubular drive cannot be set
Remedy:
Running direction on tubular drive cannot be set
Remedy:
- Delete limit positions and reset the running direction.
____________________________________________
Problem:
Tubular drive no longer moves to the lower limit position independently.
Remedy:
- Manually charge battery.
Problem:
The tubular drive only moves a few cm and then stops following a DOWN command.
Remedy:
The tubular drive only moves a few cm and then stops following a DOWN command.
Remedy:
- Manually charge battery.
Problem:
Tubular drive stops multiple times following an UP command.
Remedy:
Tubular drive stops multiple times following an UP command.
Remedy:
- Manually charge battery.
____________________________________________
This may also interest you!