Product highlights
... For the user:
Blockage detection in the UP direction (anti-freeze mechanism)
Made in Germany - for maximum reliability and durability
Soft upper stop – optimum adaptation of closing forces for fabric protection
Enables programming of 2 freely selectable intermediate positions
Compatible with sun/wind/rain sensors for maximum convenience
... For installation:
Limit positions status indicator (LSI) signals missing limit positions
Automatic shading solution length adjustment
Limit position adjustment: Automatic detection when stop or fixed point end-positions are present
Intelligent installation management permits limit position corrections
Umschaltung zwischen Rollladen- und Screenbetrieb über Steuerung möglich
Convenient threshold adjustment via the hand-held transmitter or central control units
... For planning:
Integrated radio receiver compatible with the Centronic control unit range
Centronic radio receiver integrated: compatible with Centronic range of control units
Individual, group and central control possible (also by radio)
General product data
RRP (incl. VAT)
384,00 €
Designation
P10-11-C28
Series
C28
GTIN
4251852905159
Drive diameter
Ø 35mm = P
Item number
2006 060 016 0
Sales unit
pc.
Technical data
Speed (load)
8 U/min
IP degree of protection
44
Intermediate positions
2
Power supply (AC/DC)
DC
Weight
0.85 kg
Colour
White (RAL 9016)
Power consump.
30 W
Mains frequency
0 Hz
Rated voltage
12 V
Rated current
2.5 A
Duty cycle
S2 4 min
Drive torque (Nm)
10 Nm
Speed (rpm)
11 U/min
Cable type
Rubber - S05RN-F 4x1 white
Cable length
0.15 m
Dimensions
Dimension L1
402 mm
Dimension L2
419 mm
Dimension L3
432 mm
Dimension L4
13 mm
Dimension L5
17 mm
Dimension Ø c
35 mm
Dimensional drawing
Drive adapter width from Drive adapter 40 x 1/42 x 2 (4930 300 086 0), when selecting a different drive adapter, the dimensions L2, L3 and L5 will change
Special features
Motor head can be overwrapped
Integrated charging electronics
Communication
Radio compatibility
Centronic
Obstacle detection
Blockage detection in both directions
Limit position programming
Intelligent installation management (3x approach)
LSI - limit positions status indicator
Additional features
Intermediate positions
2
Soft stop upper limit position
dynamic
Sensor functions
Sensor values - evaluable
- Sun
- Wind
- Rain
Assembly and operating instructions
Declarations of conformity
selected item
Tubular drive does not run in the right direction.
Remedy:
Problem:
Drive is not functioning.
Remedy:
Problem:
Tubular drive no longer moves to the lower limit position independently.
Remedy:
____________________________________________
Tubular drive does not run in the right direction.
Remedy:
- Tubular drive is overheated. The tubular drive is operational again after a few minutes.
- Tubular drive is faulty (does not run even after standing still for a long period of time). Replace the tubular drive.
- Clear and remove the obstruction and switch in the desired direction. Check the electrical connection.
____________________________________________
Problem:
Drive is not functioning.
Remedy:
- Program new transmitter.
- Bring transmitter within range of the tubular drive.
- Press drive or stop button on transmitter at least five times in the immediate vicinity of the tubular drive.
- Insert battery/batteries correctly in the transmitter or insert new battery/batteries.
- Check electrical connection.
- Thermal protection switch in tubular drive has tripped. Wait until the thermal protection switch in the tubular drive is reactivated.
Problem:
Running direction on tubular drive cannot be set
Remedy:
Running direction on tubular drive cannot be set
Remedy:
- Delete limit positions and reset the running direction.
____________________________________________
Problem:
Tubular drive no longer moves to the lower limit position independently.
Remedy:
- Manually charge battery.
Problem:
The tubular drive only moves a few cm and then stops following a DOWN command.
Remedy:
The tubular drive only moves a few cm and then stops following a DOWN command.
Remedy:
- Manually charge battery.
Problem:
Tubular drive stops multiple times following an UP command.
Remedy:
Tubular drive stops multiple times following an UP command.
Remedy:
- Manually charge battery.