Usage recommendation
Roller shutter
Product highlights
Two intermediate positions can be programmed
Blind mode: Two intermediate positions or one intermediate position with tilt can be programmed
Blind mode: Exact adjustment of slat angle possible
Single, group or central control unit
Function between drive and group control unit switchable
Switching times not lost in the event of power failure
Holiday function can be activated
Automatic summer/winter time adjustment
Preprogrammed date, time and switching time function
Daily, block and weekly program can be programmed
Astronomical function for morning and evening saves readjusting the switching time
Two switching times can be programmed per direction of travel and day
Komplett mit Rahmen
Large, easy-to-read display
Control button directly on the device
Changing between manual and automatic mode possible on the operating device directly
An additional operator control can be connected
Optional potential-free switching contact
Can be fitted into any flush-mounted device socket with 58 mm diameter according to DIN EN 49073 / DIN EN 60670
Adapter frame enables integration in various switch ranges
Defined drive commands possible
General product data
Designation
Centronic TimeControl TC52
GTIN
4251852907528
Item number
4032 000 003 0
Sales unit
pc.
Series
Control units
RRP (incl. VAT)
202,00 €
Technical data
Width
50 mm
Colour
White
Intermediate positions
2
Dimensions
B x H x T: 50 x 190 x 150 mm
Touch mode
Switching current max.
µ 5A / 230V / AC cos Φ = 1
Number of channels
1
Length
190 mm
Weight
0.319 kg
Type of mounting
Flush mounted
Height/depth
150 mm
IP degree of protection
20
Battery type
CR 2032
Can be integrated into the switch frame
Centronic
Mains frequency
50 Hz
Power supply (AC/DC)
Alternating current
Rated voltage
230 V
Dimensional drawing
Special features
NOT compatible with
Surface-mounted housing V3 for EC62S/EC62P
Additional features
Intermediate positions
2
Time function
Timer
Sensor functions
Manual/automatic mode changeover
Window light sensor can be connected
Sensor values - threshold settings
Sun
Sensor values - evaluable
Sun
Time function
Time function
Timer
Astronomical function
- Astro dawn
- Astro evening
Holiday function
Automatic summer/winter time changeover
Assembly and operating instructions
Declarations of conformity
Miscellaneous
Problem:
Drive is not functioning.
Remedy:
Drive is running in the wrong direction.
Remedy:
The control unit does not carry out the programmed switching commands.
Remedy:
Astro program is not switching accurately.
Remedy:
Problem:
The control unit does not carry out the programmed switching commands accurately.
Remedy:
"BATTERY" appears on the display
Remedy:
Drive is not functioning.
Remedy:
- Check the electrical connection.
____________________________________________
Drive is running in the wrong direction.
Remedy:
- Swap the drive wires for OPEN and CLOSE.
____________________________________________
The control unit does not carry out the programmed switching commands.
Remedy:
- Set the slide switch to Automatic.
- Program run times.
____________________________________________
Astro program is not switching accurately.
Remedy:
- Set correct date.
- Set correct city or exact degree of latitude/longitude.
- Switch off holiday function.
- Adjust Astro shift.
Problem:
The control unit does not carry out the programmed switching commands accurately.
Remedy:
- Switch off holiday function.
- Set the limit position in the SETTING/PROG END POSITION menu.
____________________________________________
"BATTERY" appears on the display
Remedy:
- Insert a new battery.
____________________________________________